AU-A129 - Sharp Air Conditioner Service Manual (repair manual). Page 9

Read Sharp AU-A129 Service Manual online

AH-A129E
AU-A129E
9
1. Temperature control characteristic
1-1
COOL operation
In the “COOL” mode, the thermostat circuit is
controlled by four thermostat lines (C1 thru C4).
Figure H-3
2-2
DRY operation
 On the switch on, the compressor always starts
to operate for 2 minutes with fan speed “D”
(slower than “UL”).
The microcomputer measures the room
temperature 2 minutes after this first compressor
operation. This room temperature is set as the
preset temperature automatically. The preset
temperature ranges from 18˚C to 32˚C. When
the room temperature is below 18˚C, the preset
temperature is  set to 18˚C, and when the room
temperature is over 32˚C, the preset
temperature is set to 32˚C
Dry operation is divided into three zones
(Cooling zone, Dehumidifying zone and
Circulating zone) by thermostat lines (D1 to
D3), and the compressor and the fan motor
are controlled in each zone as shown in Table
H-1.
FUNCTIONS
2. Operation modes
2-1
COOL operation
The compressor turns on or off, at the
thermostat lines C3 and C4. The outdoor fan
motor is also controlled with the compressor.
Figure H-1
1-2
DRY operation
In the “DRY” mode, the thermostat circuit is
controlled by three thermostat lines (D1 thru
D3).
Room temperature( C)
Preset temperature(˚C)
18
32
C1
C2
C3
C4
17.5
18.5
19.5
20.5
31.5
32.5
33.5
34.5
Room temperature( C)
Preset temperature(˚C)
18
32
D1
D2
D3
17.5
18.5
19.5
31.5
32.5
33.5
Figure H-2
Figure H-4
Room temperature
Preset temperature
Room 
temperature
transition
C3
C4
States 1 & 3 : Compressor ON
State 2 : Compressor OFF
1
2
3
Room temperature
Preset temperature
Room 
temperature
transition
D3
D2
D1
States 1 & 5 : Cooling zone
States 2 & 4 : Dehumidifying zone
States 3 : Circulating zone
3
4
5
1
2
Page of 28