AH-X108 - Sharp Air Conditioner Service Manual (repair manual). Page 3

Read Sharp AH-X108 Service Manual online

AH/AU-X108E
AY/AE-X108E
AH/AU-X138E
AY/AE-X138E
3
Models
INDOOR UNIT
OUTDOOR UNIT
AY-X108E
AY-X138E
AE-X108E
AE-X138E
Cooling capacity
kW
2.8 (0.9 
 3.2)
3.6 (0.9 
 3.9)
2.8 (0.9 
 3.2)
3.6 (0.9 
 3.9)
Heat pump
kW
3.7 (0.9 
 5.0)
4.8 (1.0 
 6.2)
3.7 (0.9 
 5.0)
4.8 (1.0 
 6.2)
Heating capacity
Moisture removal
Liters/h
1.1
1.3
1.1
1.3
Electrical data
Phase
-
Single
Rared frequency
Hz
50
Rated voltage range
V
198 to 264
Rated voltage
V
220 - 240
Rated current
Cool
A
4.5 - 4.1
6.2 - 5.9
4.5 - 4.1
6.2 - 5.9
Heat
A
5.0 - 4.6
7.4 - 6.9
5.0 - 4.6
7.4 - 6.9
Rated input
Cool
W
930
1220
930
1220
Heat
W
1050
1500
1050
1500
Power factor
Cool
%
94 - 95
89 - 86
94 - 95
89 - 86
Heat
%
95 - 95
92 - 91
95 - 95
92 - 91
Compressor
Type
Hermetically sealed rotary type
Model
HV237A1-S15DK
Oil charge
455cc(SUNISO 4GSD)
Refrigerant
Evaporator
Grooved tube type
system
Condenser
Corrugate Fin and Grooved tube type
Control
Capillary tube
Refrigerant volume
850g
870g
850g
870g
De-Ice system
Micro computer controled reverse system
Noise level
High
dB(A)
39
42
43
48
(at cooling)
Med.
dB(A)
33
36
-
-
Low
dB(A)
28
30
-
-
Fan system
Drive
Direct drive
Air flow
High
m
3
/min.
10.0
11.0
25.0
26.0
quantity
Med.
m
3
/min.
6.6
7.4
-
-
(at cooling)
Low
m
3
/min.
5.1
5.9
-
-
Fan
Cross flow fan
Propeller fan
Connections
Refrigerant coupling
Flare type
Refrigerant tube size Gas, Liquid
3/8", 1/4"
1/2", 1/4"
3/8", 1/4"
1/2", 1/4"
Drain pipng mm (Inches)
O.D ø 18 (45/64)
Others
Safety device
Compressor: Thermal protector
Fan motors: Thermal fuse
Fuse, Micro computer control
Air filter
Polypropylene net (Washable)
Net
Width
mm
790 (31-3/32)
728 (28-21/32)
dimensions
Height
mm
270 (10-5/8)
530 (20-7/8)
Depth
mm
188 (7-13/32)
250 (9-27/32)
Net weight
kg
9
9
32
39
Note: The condition of star( ) marked item are 'IEC 378'.
Page of 56
Display

Click on the first or last page to see other AH-X108 service manuals if exist.