AH/AU-X108E
AY/AE-X108E
AH/AU-X138E
AY/AE-X138E
2
SPECIFICATIONS
Models
INDOOR UNIT
OUTDOOR UNIT
AH-X108E
AH-X138E
AU-X108E
AU-X138E
Cooling capacity
kW
2.8 (0.9 
 3.2)
3.6 (0.9 
 3.9)
2.8 (0.9 
 3.2)
3.6 (0.9 
 3.9)
Moisture removal
Liters/h
1.1
1.3
1.1
1.3
 Electrical data
Phase
-
Single
Rared frequency
Hz
50
Rated voltage range
V
198 to 264
Rated voltage
V
220 - 240
Rated current
A
4.5 - 4.1
6.2 - 5.9
4.5 - 4.1
6.2 - 5.9
Rated input
W
930
1220
930
1220
Power factor
%
94 - 95
89 - 86
94 - 95
89 - 86
Compressor
Type
Hermetically sealed rotary type
Model
HV237A1-S15DK
Oil charge
455cc(SUNISO 4GSD)
Refrigerant
Evaporator
Grooved tube type
system
Condenser
Corrugate Fin and Grooved tube type
Control
Capillary tube
Refrigerant volume
850g
870g
850g
870g
Noise level
High
dB(A)
39
42
43
48
(at cooling)
Med.
dB(A)
33
36
-
-
Low
dB(A)
28
30
-
-
Fan system
Drive
Direct drive
Air flow
High
m
3
/min.
10.0
11.0
25.0
26.0
quantity
Med.
m
3
/min.
6.6
7.4
-
-
(at cooling)
Low
m
3
/min.
5.1
5.9
-
-
Fan
Cross flow fan
Propeller fan
Connections
Refrigerant coupling
Flare type
Refrigerant tube size Gas, Liquid
3/8", 1/4"
1/2", 1/4"
3/8", 1/4"
1/2", 1/4"
Drain pipng mm (Inches)
O.D ø 18 (45/64)
Others
Safety device
Compressor: Thermal protector
Fan motors: Thermal fuse
Fuse, Micro computer control
Air filter
Polypropylene net (Washable)
Net
Width
mm
790 (31-3/32)
728 (28-21/32)
dimensions
Height
mm
270 (10-5/8)
530 (20-7/8)
Depth
mm
188 (7-13/32)
250 (9-27/32)
Net weight
kg
9
9
32
39
Note: The condition of star( ) marked item are 'IEC 378'.