(2) Dust detection by using the sensor
The output voltage from the optical allergen sensor is input into the indoor unitÅfs microcomputer to detect the air
contamination (dust). This method inputs the sensor voltage per unit of time and calculates the relative fluctuation
to determine whether the air is contaminated or not.
contamination (dust). This method inputs the sensor voltage per unit of time and calculates the relative fluctuation
to determine whether the air is contaminated or not.
(3) Operation of the indoor unit's microcomputer
As with the odor sensor, the indoor unitÅfs microcomputer starts constantly detecting the air contamination level
after 1 minute of the operation start.
after 1 minute of the operation start.
(4) Switching sensitivity of the optical allergen sensor
The sensitivity can be adjusted. However, both sensors will be adjusted to the same level. The air contamination is
detected in the following seconds at each sensor level.
detected in the following seconds at each sensor level.
Clean
Contaminated
Determined
clean
clean
Determined
contaminated
contaminated
Reference
value
value
High (2 sec.)
Med (3 sec.)
Low (4 sec.)
Med (3 sec.)
Low (4 sec.)
15k
Ω
15k
Ω
13k
Ω
13k
Ω
R7
R6