27
Zone Compressor intermittent time
Fan
After "3 min. on - 3 min.off" 
is repeated 4 times, the 
compressor goes off, and 
only the fan continues to 
repeat “3 min. on - 8 
min.off”.
 
J
K
3 min. on - 3 min. off
3 min. on - 8 min. off
Same as Compressor
1-4 Automatic operation
The operating mode and temperature setting are
determined by the room temperature and the external
air temperature.
The operating mode will changeover automatically
with the following conditions.
Set temp.
(24˚C)
Set temp.
(23˚C)
Set temp.
(22˚C)
(Outdoor temp.)
27.8
26.8
28.8
[˚C]
0
10
[˚C]
(Indoor temp.)
1. From cooling to heating
Cooling mode will changeover to heating mode when
condition of indoor temperature 1.8˚C lower than the
set temperature conditions for 5 minutes.
2. From heating to cooling
Heating mode will change over to cooling mode when
condition of indoor temperature 4.8˚C higher than the
set temperature conditions for 25 minutes under Hot
keep condition.
10
Set temp.
(26˚C)
Set temp.
(25˚C)
Set temp.
(24˚C)
Set temp.
(25˚C)
Set temp.
(26˚C)
(Outdoor temp.)
22.3
22.2
22.4
[˚C]
18
28
34
[˚C]
(Indoor temp.)
When the set temperature is adjusted within the range
of 
±
2˚C by the remote control's key. ( 
), the
changeover judgement room temp. will also be shifted
within the range of 
±
2˚C.
1-5 ON-timer
The ON-timer is set by pressing the ON-timer button.
In order to attain the set temperature at the set time,
the operation starting time is corrected by neuro and
fuzzy computing one hour before the set time.
1-6 OFF-timer
The OFF-timer is set by pressing the OFF-timer
button. Operation is as follows:
Cooling
Heating
Set temperature
By fuzzy computing
Set the shift up time
Cooling setting + 1°C
Heating setting - 3°C
Final
Dry
Same as above 
(Final setting + 1°C)
*During Heating
3°C
Room 
temperature
Timer set time
1
hour
Timer operation starts
Stops
*During Cooling / Dry
1°C
Stops
Timer set time
1
hour
Timer operation starts
Room 
temperature
1-7 Swing louvre
The louvre is moved by a stepping motor to perform
swing and fixing in the set position.
If the "FLOW DIRECTION" button is prossed during
swing, it will stop. If the "FLOW DIRECTION" button is
prossed while it is stopped, it will swing.
1-8 Restart control
Once the compressor stops, this control prevents it
from starting again for 3 minutes. It also prevents
starting for 80 seconds immediately following plugging
into the power outlet.
1-9 One-hour operation
If this button is pressed when operation is
stopped, operation will begin and then stop after 1
hour. If pressed when it is operating, will stop after
one hour.
1-10
Full power operation
Immediately begins cooling or heating at
maximum power and air flow. Full power stops
after 1 hour.
(During heating) Operates at setting of 32
°
C.
(During cooling) Operates at setting of 18
°
C.
(24˚C) (23˚C) (22˚C)
Cooling
(25˚C)
FAN ONLY
Cold
(25˚C)
(Room temperature 
- 2
°
C)
Cooling
Cooling
(Dry)
Room 
temperature
(˚C)
21
29
0
16
18
(24˚C)
(25˚C)
(26˚C)
28
34
External air 
temperature (
°
C)
The external air temperature is determined by 
detecting the temperature of the outdoor heat 
exchanger.
Heating
Page of 56
Display