27
AY-M09AE
AE-M18AE
Figure P-4. At Heating for AY-M18AE (2 units running)
Figure P-3. At Heating for AY-M09AE (1 unit running)
REFRIGERANT PIPE INSTALLATION WORKS
Refrigerant pipe length and level difference between the indoor and outdoor units.
The shorter refrigerant pipe, the higher the machine capabillity. Keep the pipeline as short as possible.
If actual pipe length exceeds 7.5 m, add refrigerant(R-22), 15g per 1 m.
PIPE SIZE
GAS
LIQUID
3/8"
1/4"
10 m
5 m
STANDARD PERMISSIBLE
LENGTH
PERMISSIBLE LEVEL
DIFFERENCE
Indoor air temp. : 20˚C
Indoor fan speed : Hi
3400
5100
6800
8500
10200
11900
13600
Heating capacity(BTU/h)
3400
5100
6800
8500
10200
11900
13600
Heating capacity(BTU/h)
1.0
1.5
2.0
2.5
3.0
3.5
4.0
(kW)
Input(W)
45
40
35
30
25
20
Outside air temp.(˚C)
Outlet air temp.(˚C)
- 5
0
5
7
1 0
- 5
0
5
7
1 0
Power source : 1ø 220V, 50Hz
1300
700
1000
Indoor air temp. : 20˚C
Indoor fan speed : Hi
1.0
1.5
2.0
2.5
3.0
3.5
4.0
(kW)
Input(W)
45
40
35
30
25
20
Outside air temp.(˚C)
Outlet air temp.(˚C)
Power source : 1ø 220V, 50Hz
2300
1500
2000