AE-M18 (serv.man2) - Sharp Air Conditioner Service Manual (repair manual). Page 20

Read Sharp AE-M18 (serv.man2) Service Manual online

20
AY-M09AE
AE-M18AE
Self-diagnosis table (error information call-up)
: Turns ON.
Display with operation LED of 
indoor unit
It is ON at the same time 
when timer LED is ON.
Outdoor unit display LED
LED 1
Room 
A1
Serial
SIGNAL
LED 2
Room 
A2
Serial
SIGNAL
LED 3
Error
display
Diagnosis content
Content
Relevant
unit
Indoor
Outdoor
Indoor
Outdoor
Outdoor
No current flows in 
the compressor.
Indoor or 
outdoor
Check item
Remedy
: Turns OFF.
: Flickering at 2 seconds intervals.
: Flickering at 0.2 seconds intervals.
Error
No.
1
2
3
4
5
6
x
1
2
3
4
4 sec.
OFF
5
x
x
x
Outdoor thermistor is 
defective. Open circuit
Outdoor thermistor is 
defective. Short circuit (0
)
Indoor thermistor is defective. 
Short circuit (0
)
Indoor thermistor is defective. 
Open circuit
Wiring connection 
between the unit is improper.
Compressor is locked.
Indoor fan motor rotates 
poorly.
No diagnosis information.
(1) Does indoor fan rotate ?
(2) Check the running capacitor.
(3) 
Check the wiring and correction of the power supply to the compressor.
(2) Replace the running capacitor.
(3) Connect the wiring connection.
(4) Replace the compressor.
(2) 
Unless LED flickers or lights, the outdoor control 
      circuit does not operate. 
      
Refer to trouble shooting flow chart in Page 21 ~ 23.
(1) 
Check the voltage of the power supply for 198 to 264V. 
       Check that the voltage drops when the compressor is started.
(1) Correct the wiring between the unit.
(2) Is LED 1 or LED 2 ON on the outdoor unit ?
(1) Check the connection of the  
      thermistor connector CN4.
(2) Check the resistance of the  
      thermistor.
(1) Check the connector of the  
      thermistor connector CN5.
(2) Check the resistance of the  
      thermistor.
(1) Is RY1(room A1) or RY2(room A2) on ?
(For check try to TEST RUN the indoor unit.)
(2) 
Check the connection of compressor from RY1 and RY2.
(3) Check compressor motor protector for activation.
(2) Check the connected and soldered state of CN5.
(3) Is rotation pulse input to the terminals No. 2 and 3 
     of CN5. ?
(1) Fan or fan motor locked           Replace
(1) Improve the power supply.
(1) 
Since the parts of the control circuit may be 
      broken, replace the control circuit in the indoor 
      and outdoor units.
      For the circuit repairing method, refer to Page 19.
(1) Improve connection state.
(2) Replace the thermistor.
(1) Improve connection state.
(2) Replace the thermistor.
(1) Replace the outdoor control board unit.
(2) Connect the wiring connection.
(3) Connect the cause of the overloaded 
     operation.
(2) Correct the connecting solder or replace the 
     control board unit.
CHARACTERISTIC OF TH1 & TH2
0 -10
0
10
20
30
40˚C
20
40
60
80
100
120
k
25˚C
15k
Page of 40