TX-29PM1D, TX-29PM1F, TX-29PM1P - Panasonic TV Service Manual (repair manual). Page 15

Read Panasonic TX-29PM1D / TX-29PM1F / TX-29PM1P Service Manual online

SCHEMATIC DIAGRAMS FOR MODELS
TX-29PM1D, TX-29PM1F, TX-29PM1P
(CP-521F CHASSIS)
NOTE
1.
RESISTOR
All resistors are carbon ¼W resistor, unless marked otherwise.
Unit of resistance is OHM ( ) (k=1,000, M=1,000,000)
2.
CAPACITORS
All capacitors are ceramic 50V unless marked otherwise.
Unit of capacitance is  F unless otherwise stated.
3.
COIL
Unit of inductance is  H, unless otherwise stated.
4.
EARTH SYMBOL
Chassis Earth (Cold)
Line Earth (Hot)
5.
VOLTAGE MEASUREMENT
Voltage is measured by a d.c. voltmeter.
Measurement conditions are as follows:
Power source
a.c. 220V-240V, 50Hz
Receiving Signal
Colour Bar signal (RF)
All customer controls
Maximum position
These schematic diagrams are the latest at time of printing and are subject to change without notice.
REMARKS
a.
Do not touch the hot part, or the hot and cold parts at the same time, as you are liable to a shock hazard.
b.
Do not short circuit the hot and cold circuits as electrical components may be damaged.
c.
Do not connect an instrument, such as an oscilloscope, to the hot and cold circuits simultaneously as this may cause
fuse failure. Connect the earth of the instruments to the earth connection of the circuit being measured.
d.
Make sure to disconnect the power plug before removing the chassis.
NOTE
1. The Power Supply Circuit contains a circuit area, which uses a separate power supply to isolate the earth connection.
The circuit is defined by HOT and COLD indications in the schematic diagram. All circuits, except the Power Circuit, are 
COLD.
IMPORTANT SAFETY NOTICE
Components identified by
 mark have special characteristics
important for safety. When replacing any of these components, use
only manufacturers' specified parts.
15
Page of 17
Display