5.8. COLOUR PURITY
 1. Set Bright and Contrast controls to their maximum
positions.
 2. Operate the TV set over 15 minutes.
 3. Full degauss the picture tube by using an external
degaussing coil. By rotating R-B static convergence
magnet.
 4. Apply a crosshatch pattern signal and adjust roughly the
static convergence magnets.
 5. Apply a green pattern signal.
 6. Loosen a clamp screw for the deflection yoke and move the
deflection yoke as close to the purity magnet as possible.
 7. Adjust the purity magnet so that a vertical green field is
obtained at the center of the screen.
 8. Slowly press the deflection yoke and set it where a uniform
green field is obtained.
 9. Adjust roughly the Low Light controls and make sure that a
uniform white field is obtained.
 10. Tighten the clamp screw.
5.9. CONVERGENCE
 1. Apply a crosshatch pattern signal and set Contrast control
to the maximum position.
 2. Adjust Bright control to obtain a clear pattern.
 3. Adjust Red and Blue line at center of the screen.
 4. Adjust Red and Blue with Green line at center of the screen
by rotating (RB)-G static convergence magnet.
 5. Lock convergence magnets with silicone sealer.
 6. Remove the DY wedges and slightly tilt the deflection yoke
vertically.
 7. Fix the deflection yoke by re-inserting the DY wedges.
 8. If purity error is found, repeat “Colour Purity” adjustment.
Before Colour Purity, Convergence and White Balance adjustments are attempted, V. Center, V. Height, H. Width, H. Center and Focus
adjustments must be completed.