Battery Monitor Check
-
1. Apply 2.25 V between BATT+ and BATT-.
2. Execute the command 
sendchar PAD
sendchar LED 0
sendchar CRX 0 1
sendchar AD1
It assumes that the return value is XX.
a) XX: 70: No need to adjust
b) XX: 66 ~ 6F: Need to adjust
XX: 71 ~ 7A: Need to adjust
Write AD value of 2.25 V to EEPROM.
ex) read data: XX = 6A, write data: YY = 6A
read data: XX = 73, write data: YY = 73
EEPROM = 0009(Low Voltage) write “YY”
Execute the command “wreeprom 00 09 01 YY”.
EEPROM = 000A(No Voltage) write “YY -C"
Execute the command “wreeprom 00 0A 01 ZZ”. 
for model with Power Falure Talk, add:
EEPROM = 000B (Low Voltage for PSPLY)
Write YY + A
Execute the command "wreeprom 00 0B 01 XX".
Note:
ZZ = YY - C
XX = YY + A
XX: 7B ~ FF: Reject
IC1, F1, R45
(G)
Battery Low 
Confirmation
-
1. Apply 2.40 V between BATT+ and BATT-.
2. Confirm that there is no flashing of Battery Icon.
3. Apply 2.25 V ± 0.08 V between BATT+ and BATT-.
4. Confirm that there is flashing of Battery Icon.
IC1, F1, R45
(H)* BBIC Clock Adjustment
CKM
1. Apply 2.6 V between BATT+ and BATT- with DC power.
2. Input Command “sendchar sfr”, then you can confirm the current value.
3. Check X’tal Frequency. (10.368 MHz ± 100 Hz).
4. If the frequency is not 10.368 MHz ± 100 Hz, adjust the frequency of CKM
executing the command “sendchar sfr xx xx (where xx is the value)” so that the
reading of the frequency counter is 10.368000 MHz ± 5 Hz.
Note:
Clear the registered information for Base Unit before measurement, because the
Frequency will not possibly get stable due to the registered information.
Pressing the button of "3" "5" "7" "#"clears the registration.
Register to it on Base Unit after measurement. 
IC1, X1, C47
 
(I)*
Transmitted Power 
Confirmation
-
Short Antenna pattern to GND.
1. Configure the DECT tester (CMD60) as follows;
<Setting>
• Test mode: PP
• RFPI: 0102030405
• Traffic Carrier: 5
• Traffic Slot: 4
• Mode: Loopback
• RF LEVEL = -70 dBm
• PACKET: PP32Z
2. Execute the command “sendchar TST 01 02 03 04 05".
3. Initiate connection from DECT tester.
4. Confirm that the NTP value at ANT is 19 dBm ~ 25 dBm.
IC1, C801, 
C859, C860, 
C861, C862
(J)*
Modulation Check and 
Adjustment
-
Follow steps 1 to 3 of (I).
4.Confirm that the B-Field Modulation is -350 ± 50/+350 ± 50 kHz/div using data
type Fig 31.
Refer to (I)
(K)*
Frequency Offset 
Confirmation
-
Follow steps 1 to 3 of (I).
4.Confirm that the frequency Offset is < ± 20 kHz.
Refer to (I)
(L)*
Sensitivity Receiver 
Confirmation
-
Follow steps 1 to 3 of (I).
4.Set DECT tester power to -88 dBm.
5.Confirm that the BER is < 1000 ppm.
Refer to (I)
(M)*
Power RAMP 
Confirmation
-
Follow steps 1 to 3 of (I).
4.Confirm that Power RAMP is matching.