(H)* BBIC Clock Adjustment
(Important)
P1.0
CLK
CLK
1. Apply 2.6V between BATTERY (+) and BATTERY (-) with DC power.
2. Execute the command “EnableClockOutput”.
3. Input Command “sfr", then you can confirm the current value.
4. Check X’tal Frequency. (10.368 MHz ± 100 Hz).
5. If the frequency is not 10.368 MHz ± 100 Hz, adjust the frequency of CLK
2. Execute the command “EnableClockOutput”.
3. Input Command “sfr", then you can confirm the current value.
4. Check X’tal Frequency. (10.368 MHz ± 100 Hz).
5. If the frequency is not 10.368 MHz ± 100 Hz, adjust the frequency of CLK
executing the command “setfreq xx xx (where xx is the value)” so that the
reading of the frequency counter is 10.368000 MHz ± 5 Hz.
Note:
* How to de-registration (link to base unit)
1) Push handset: menu
reading of the frequency counter is 10.368000 MHz ± 5 Hz.
Note:
* How to de-registration (link to base unit)
1) Push handset: menu
# 1 3 1
2) Push handset: 0
0 0 0
3) Select handset you want to de-regist.
After push OK.
Register to it on Base Unit after measurement.
After push OK.
Register to it on Base Unit after measurement.
C127, C122,
C123, X101,
IC103
C123, X101,
IC103
(I)* Transmitted Power
Confirmation
ANT
Short the ANT-Short and ANT-Short-GND before starting steps from 1 to 5.
1. Configure the DECT tester (CMD60) as follows;
<Setting>
• Test mode: PP
• RFPI: 0102030405
• Traffic Channel: 5
• Traffic Slot: 4
• Mode: Loopback
• RFPI: 0102030405
• Traffic Channel: 5
• Traffic Slot: 4
• Mode: Loopback
2. Execute the command “testmode”.
3. Initiate connection from DECT tester.
4. Confirm that the NTP value at ANT is -19dBm ~ 25dBm.
3. Initiate connection from DECT tester.
4. Confirm that the NTP value at ANT is -19dBm ~ 25dBm.
C814, C812,
IC103, C813,
C807, C819,
C826, D803,
C817, C149,
RA801, C823,
C803, C825,
C110, C802,
C804, C821,
C820, C815
IC103, C813,
C807, C819,
C826, D803,
C817, C149,
RA801, C823,
C803, C825,
C110, C802,
C804, C821,
C820, C815
(J)* Modulation Check
ANT
Follow steps 1 to 4 of (I).
4. Confirm that the B-Field Modulation is 340kHz/div ~ 402kHz/div using data
type Fig31.
type Fig31.
C814, C812,
IC103, C813,
C807, C819,
C826, D803,
C817, C149,
RA801, C823,
C803, C825,
C110, C802,
C804, C821,
C820, C815
IC103, C813,
C807, C819,
C826, D803,
C817, C149,
RA801, C823,
C803, C825,
C110, C802,
C804, C821,
C820, C815
(K)* Frequency Offset
Confirmation
-
Follow steps 1 to 4 of (I).
4. Confirm that the frequency offset is -50kHz ~ +50kHz.
C814, C812,
IC103, C813,
C807, C819,
C826, D803,
C817, C149,
RA801, C823,
C803, C825,
C110, C802,
C804, C821,
C820, C815
IC103, C813,
C807, C819,
C826, D803,
C817, C149,
RA801, C823,
C803, C825,
C110, C802,
C804, C821,
C820, C815
(L)* Sensitivity Receiver
Confirmation
-
Follow steps 1 to 4 of (I).
4. Set DECT tester power to -85dBm.
5. Confirm that the BER is < 1000ppm.
5. Confirm that the BER is < 1000ppm.
C814, C812,
IC103, C813,
C807, C819,
C826, D803,
C817, C149,
RA801, C823,
C803, C825,
C110, C802,
C804, C821,
C820, C815
IC103, C813,
C807, C819,
C826, D803,
C817, C149,
RA801, C823,
C803, C825,
C110, C802,
C804, C821,
C820, C815
(M)* Timing Confirmation
-
Follow steps 1 to 4 of (I).
4. Confirm that the Timing accuracy is < ± 2.0ppm.
C814, C812,
IC103, C813,
C807, C819,
C826, D803,
C817, C149,
RA801, C823,
C803, C825,
C110, C802,
C804, C821,
C820, C815
IC103, C813,
C807, C819,
C826, D803,
C817, C149,
RA801, C823,
C803, C825,
C110, C802,
C804, C821,
C820, C815
Items
Adjustment
Point
Procedure
Check or
Replace Parts
Click on the first or last page to see other KX-TG1611UAF / KX-TG1611UAH / KX-TG1611UAR / KX-TG1611UAW / KX-TG1612UAH / KX-TGA161RUF / KX-TGA161RUH / KX-TGA161RUR / KX-TGA161RUW (serv.man2) service manuals if exist.