KX-TCD715RUM - Panasonic Telephone Service Manual (repair manual). Page 64

Read Panasonic KX-TCD715RUM Service Manual online

15.3.6.  PSTN Line
Address
Default
Name
Type
Description
0F00
03
UserCfg-1.Mode
D
User configuration (MMI) - mode settings 1.
Bit
0 : "R" mode, 0=earth break, 1=loop break
2..1: Dial mode, 00:pulse, 01:DTMF
3..7: Reserved
0F01
0D
UserCfg-2.Mode
D
User configuration (MMI) - mode settings 2.
Bit
0..1: short "R" key time selection
00= short, 01=long, 10=extra-long
2..3: long "R" key time selection
00= short, 01=long, 10=extra-long,
11=undef (uses same time as specified for short R key)
4..7: Reserved
Defaults to 0000 1101
0F02
10
UserCfg.RPauseTime
D
User configuration (MMI) - "R"-pause. If disabled, normal
dial pause (DialPauseTime) is used.
Bit 7..0 : "R" pause time, zero value allowed
Unit : 50 ms, defaults to 800 ms.
0F03
03
UserCfg.DialPauseTime
D
User configuration (MMI) - dial pause.
Bit 3-0 : dial pause in 1 sec units , zero not allowed.
Bit 7-4 : unused
Defaults to 3 seconds
0F04
0F
Cfg-1
D
PSTN line configuration 1 (factory settings)
Bit
0: EarthBreakEnable , Earth break 1=enable 0=disable
1:LoopBreakEnable, Loop break 1=enable,0=disable
2:PulseDialEnable, Pulse dial 1=enable 0=disable
3:RPauseEnable, usage of "R" pause 1=enable, 0=disable
4:PulseType,0=normal puls-type
1=(’0’=1 pils,..’9’=10 puls’s).
5: InterDigitLowImp. controls interdigit impedance.
1: keep low-impedance during interdigit pause
0: normal impedance during interdigit pause
6:
LowImpLineSeizure.
Special
low-imp
line
seizure
(Australian) , 1=enable , 0=disable
7: TwoLines. line config 0=one line, 1=two lines Defaults to
0000 0111B.
0F05
15
Cfg-2
PSTN line configuration 2 (factory settings)
Bit
0: Meter-pulse, 1=enable, 0=disable
1: DialToneMode, dial tone detection 1=enable 0=disable
2: BusyToneMode. busy tone detection 1=enable 0=disable
3: CurrentLimiterMode, 1=enable, 0=disable
4: RingToneMode. Ring tone detection 1=enable 0=disable
5: HookRelayEnable, 1=enable, 0=disable (if same port is
used
for
earth-control
EarthBreakEnable
and
HookRelayEnable cannot both be set to 1).
6..7: not used
Defaults to 0001 0101B.
0F06
28
MakeTime
D
Pulse make time.
Unit : 1 ms. defaults to 40 ms.
0F07
3C
BreakTime
D
Pulse break time
Unit : 1 ms, defaults to 60 ms.
0F08
64
DtmfTime
D
DTMF tone pulse time.
Unit : 1 ms, defaults to 100 ms.
0F09
0A
InterDigitDtmfTime
D
Inter-digit time in DTMF mode.
Unit : 10 ms , defaults to 100ms.
0F0A
4A
InterDigitPulseTime
D
Inter-digit time in Pulse mode.
Unit : 10 ms, defaults to 740 ms.
0F0B
08
CalibBreakTime[0]
D
Calibrated loop-break time for short break
Unit : 10 ms, defaults to 80 ms.
0F0C
14
CalibBreakTime[1]
D
Calibrated loop-break time for long break
Unit : 10 ms, defaults to 200 ms.
0F0D
46
CalibBreakTime[2]
D
Calibrated loop-break time for extra-long break
Unit : 10 ms, defaults to 700 ms.
0F0E
28
CalibBreakTime[3]
D
Calibrated earth-break time for short break
Unit : 10 ms, defaults to 400 ms.
0F0F
82
CalibBreakTime[4]
D
Calibrated earth-break time for long break
Unit : 10 ms, defaults to 1300 ms.
0F10
82
CalibBreakTime[5]
D
Calibrated earth-break time for extra-long break
Unit : 10 ms, defaults to 1300 ms.
0F11
FF
LineSeizureEndTime
D
Line seizure end-time - time after hook-on. Meter-pulse
detection continues during this period of time. 00h or FFh
means 10 ms.
Unit : 10 ms, defaults to 10 ms.
64
KX-TCD715RUM
Page of 93
Display