Read Panasonic WR-X22NL / WR-X22NH Service Manual online
– 4 –
R
SIGNAL
GND
L
8
1
1
2
R
L
2
7
6
5
4
3
2
1
L
R
L
4
3
2
1
R
-10dB
-60dB~-20dB 10k
Ω
(WITH PHANTOM)
-60dB~-20dB 10k
Ω
: MIC
-30dB~+10dB 10k
Ω
: LINE
10k
Ω
+
4dB 10k
Ω
+
4dB 10k
Ω
+
4dB 10k
Ω
OUT
IN
MAIN OUT
+4dB 600
Ω
SUB OUT
REC OUT
STEREO INPUT
MONO INPUT
REMOTE
PATTERN CONTROL
+4dB 600
Ω
0dB is referenced to 0.775Vrms.
RETURN
SEND
SUB IN
+10/0/-10dB 10k
Ω
REMOTE PIN CONNECTION
EXT CONT.
PIN CONNECTION
CONT. COM
(NC)
(NC)
(NC)
(NC)
(NC)
(NC)
(NC)
NO.1 : GND
NO.2 : HOT
NO.3 : COLD
NO.2 : HOT
NO.3 : COLD
■
Input/Output Connectors
@9
Mono Input Connector (7 and 8) [MONO INPUT 7 and
8]
8]
Connects with a microphone. When the phantom power
switch o is set to on, the phantom power (+48 V) for a
condenser microphone is supplied (then, a condenser
microphone that requires external power supply can be
used).
switch o is set to on, the phantom power (+48 V) for a
condenser microphone is supplied (then, a condenser
microphone that requires external power supply can be
used).
Mono:
2 circuits
Input connector:
XLR-3-31 type
Electronic balance w PIN hot
Electronic balance w PIN hot
Input level:
–60 dB to –20 dB
Impedance:
10 k
Ω
Cautions:
• Toggle the switch on only when using a condenser
microphone that requires external power supply.
Use a balanced type condenser microphone.
Use a balanced type condenser microphone.
• Refer to the operating instructions for a condenser
microphone when using it.
#0
Mono Input Connectors (1 to 6)
[MONO INPUT 1 to 6]
[MONO INPUT 1 to 6]
Up to 6 monaural line devices such as a microphone
and wireless microphone receiver can be connected.
The level switch q toggles the level between micro-
phone and line.
and wireless microphone receiver can be connected.
The level switch q toggles the level between micro-
phone and line.
Mono:
6 circuits
Input connector:
XLR-3-31 type
Electronic balance w PIN hot
Electronic balance w PIN hot
Input level microphone:
–60 dB to –20 dB
Line:
–30 dB to +10 dB
Impedance:
10 k
Ω
#1
Remote Output Connector [REMOTE]
Collectively controls the system power by connecting
the connector to the external control terminal of the
power control unit.
the connector to the external control terminal of the
power control unit.
@5
Power Cord
Be sure to put a breaking device when connecting
AC110 V - 120 V (NL) or AC220 V - 240 V (NH) with 50
Hz or 60 Hz.
Connection of the power cord should be established by
any of the following methods.
AC110 V - 120 V (NL) or AC220 V - 240 V (NH) with 50
Hz or 60 Hz.
Connection of the power cord should be established by
any of the following methods.
(1) Connect the power cord to the power control unit.
(2) Install the unit near a receptacle and connect the
(2) Install the unit near a receptacle and connect the
power cord to the receptacle via a breaking device.
The breaking device should be installed near an
operator.
The breaking device should be installed near an
operator.
(3) Connect the power cord to a circuit breaker in a
panelboard that has a contact distance of 3.0 mm or
more. Use a circuit breaker by which every circuit of
the main power supply except a ground-protective
conductor should be broken.
more. Use a circuit breaker by which every circuit of
the main power supply except a ground-protective
conductor should be broken.
@6
Grounding Terminal [SIGNAL GND]
Connect this terminal to a ground such as the rack.
@7
Main Output Connectors [MAIN OUT 1 L/R, MAIN
OUT 2 L/R]
OUT 2 L/R]
Is a connector for main output that is mixed by the unit.
Stereo:
2 circuits
Output connector:
XLR-3-32 type
Electronic balance w PIN hot
Electronic balance w PIN hot
Output level:
+4 dB
Applicable impedance:
600
Ω
or more
@8
Sub Output Connectors [SUB OUT 1, 2]
Is a connector for sub output that is mixed by the unit.
Mono:
2 circuits
Output connector:
XLR-3-32 type
Electronic balance w PIN hot
Electronic balance w PIN hot
Output level:
+4 dB
Applicable impedance:
600
Ω
or more
@7
@8
@9
#0
@5
@6
#2
#1
#3
#4
#5
#6
#7
Click on the first or last page to see other WR-X22NL / WR-X22NH service manuals if exist.