MECH-5 
 
4.  Supply DC6V-9V to the Measuring Board(VFK1308P). Please use the DC cable(VJA0941) and AC Adaptor to 
supply DC voltage to Measuring Board. 
5.  Connect the oscilloscope to the Measuring Points [ENVELOPE] and [HID] as a trigger on the Measuring Board 
(VFK1308P). 
6.  Play back the color bar alignment tape and confirm that the Envelope is within the following specifications. 
 
 
 
 
 
 
 
 
 
 
7.  If it is out of the specification, adjust the height of the S1 and T1 Post. 
 
<NOTE: Insertion of cassette tape> 
To adjust height of S1 and T1 post, below indicated operation is required. 
1.  Set to VCR mode in camera recorder and open the cassette holder. 
2.  Insert DV color bar alignment tape and confirm that the camera recorder is in the loading completion condition. 
3. Open the “7. ADJUST MENU” and select the item “ATF GAIN”
4.  Press the OPERATION LEVER. 
5. Message “NOW SERVO ADJUST PUSH MENU TO RETURN” is appeared on screen and tilt the OPERATION 
LEVER in UP(PLAY) direction to playback the tape. 
6.  Press MENU button 3 times to return normal screen mode. 
7.  Remove the rubber on Grip Cover Unit. 
8.  Unscrew the screw (A) and remove the plate from frame. 
9.  Unscrew the 2 screws (B) and remove the Mecha Dustproof Cover. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Screw (A) 
Plate 
Pull out 
plate to 
this 
direction 
Rubber 
Mecha Dustproof 
Cover 
Screws (B) 
Make as flat as possible 
V1/V max. 0.9 
V2/V max. 0.9 
V3/V max. 0.9 
Page of 127