Read Panasonic AG-DVX100AP / AG-DVX100AN / AG-DVX100AE / AG-DVX100EN / AG-DVC180AMC Service Manual online
DIS-1
1. Note when inserting Flexible
Cable
There are five flexible cables, which have two sets of
contacts on each cable, see the figure below. When
inserting these cables into the connector, make sure
that the cables are fully inserted, if not they may
damage the connector.
contacts on each cable, see the figure below. When
inserting these cables into the connector, make sure
that the cables are fully inserted, if not they may
damage the connector.
P52 on EVR CONNECT C.B.A.
P4604 and P4606 on R_SIDE C.B.A.
P1004 and P1006 on CAMERA C.B.A.
P4604 and P4606 on R_SIDE C.B.A.
P1004 and P1006 on CAMERA C.B.A.
CCD
←→
P1004
LENS
←→
P1005
LCD Unit
←→
P4606
P52 (EVR CONNECT C.B.A.)
←→
P4604 (R_SIDE C.B.A.)
When P1004 flexible cable is not making correct
contact, the camera's picture will not be seen.
When P1005 flexible cable is not making correct
contact, the LENS will not operate.
When P4606 flexible cable is not making correct
contact, the LCD Panel will not operate.
When P52 or P4604 flexible cable is not making
correct contact, the VTR will not operate.
If any of the above symptoms occur after you
assemble the camera recorder, please check the
indicated connector.
2. Type of Screws
As for this procedure, a screw is described by the
alphabet. The specified screw, refer to the table below
about any type. When constructive, be careful not to
mistake to put a screw.
alphabet. The specified screw, refer to the table below
about any type. When constructive, be careful not to
mistake to put a screw.
TYPE Figure Apply
to
screw
A
A, B, C, D, E, K, L,
M, P, Y
B
H, I, J, N, O, V, W,
Z
C F
D G
E R
F T
G G
H S
CONNECTOR
FLEXIBLE CABLE
(REAR SIDE)
TWO CONTACT
POINTS
POINTS
BLACK
4mm
SILVER
4mm
BLACK
6mm
SILVER
6mm
BLACK
4mm
GOLD
6mm
GOLD
6mm
GOLD
5mm
Click on the first or last page to see other AG-DVX100AP / AG-DVX100AN / AG-DVX100AE / AG-DVX100EN / AG-DVC180AMC service manuals if exist.