INF-7
4. LITHIUM BATTERY
4-1. Replacement Procedure
1.
Remove the EVR CONNECT C.B.A. (Refer to item “14. Removal of EVR CONNECT C.B.A.” in section 2).
2.
Unsolder the Lithium battery “Ref No: B51/Part No: VSB0407” and then replace with the new one.
NOTE:
The lithium battery is a critical component.
It must never be subjected to excessive heat of discharge.
It must therefore only be fitted in equipment designed specifically for its use.
Replacement batteries must be of the same type and manufacture.
They must be fitted in the same manner and location as the original battery, with the correct polarity contacts
observed.
Do not attempt to re-charge the old battery or re-use it for any other purpose.
It should be disposed of in waste products destined for burial rather than incineration.
CAUTION
Danger of explosion if battery is incorrectly replaced.
Replace only with the same or equivalent type recommended by the equipment manufacturer.
Discard used batteries according to manufacture’s instructions.
Replace only with the same or equivalent type recommended by the equipment manufacturer.
Discard used batteries according to manufacture’s instructions.
LITHIUM BATTERY
EVR CONNECT C.B.A.
IC2003<3>
(REAL TIME CLOCK)
(REAL TIME CLOCK)
LIBATT
36A
36B
P2001 P56
EVR CONNECT C.B.A
SYSCON C.B.A
(LI-BATT)
B51
If input voltage is become less than 2.0V, warning information is displayed.
Lithium battery is charge/discharge type, therefore no require exchange it as maintenance part.
<INFORMATION>