Read Panasonic AG-DVX100AP / AG-DVX100AN / AG-DVX100AE / AG-DVX100EN / AG-DVC180AMC Service Manual online
INF-1
1. SERVICING FIXTURES AND TOOLS
The following servicing tools are required for mechanical and electrical servicing and alignment.
The items marked “NEW” in the following list are necessary for the AG-DVX100A and AG-DVC180A.
Please refer to “Y” and “N” in table below, which tools required for servicing the NTSC and PAL model.
1-1. Summary Table of Servicing Fixtures and Tools
No
Parts No.
NAME
NTSC
Model
PAL
Model
PURPOSE
REMARK
1
VFM3010EDS
DV Alignment Tape (Color bar)
Y
N
Electrical Adjustment
2
VFM3110EDS
DV Alignment Tape (Color bar)
N
Y
Electrical Adjustment
3
VFM3000EDS
DV Alignment Tape (Linearity)
Y
Y
Tape Interchangeability Adjustment
4
VFK1217
Tape End/Beg Detect Cassette
Y
Y
Sensor Sensitivity Adjustment
5
*VFK1811B
EVR Adjustment Software
Y
N
PC Electrical Adjustment System
NEW, NOTE 1
Download from WEB site.
Download from WEB site.
6
*VFK1840A
EVR Adjustment Software
N
Y
PC Electrical Adjustment System
NEW, NOTE 2
Download from WEB site.
Download from WEB site.
7
*VFK1481K
LISTA Software
Y
Y
LISTA Adjustment
Download from WEB site.
8
VFK1308P
Measuring Board
Y
Y
Test point Board and PC I/F
9
VFK1309A
EVR Connector Board
Y
Y
Connection for PC Adjustment
NOTE 3
10 VFK1694
EVR Extender Board
Y
Y
Connection for PC Adjustment
11 VJA0941
DC Cable
Y
Y
Power Supply for Measuring Board
12 VFK1317
30pin Flat Cable
Y
Y
Between Meas. & Con. Boards
13 VFK1809
72mm Attachment Ring
Y
Y
Camera Adjustment
14 VFK1164TAR43 43mm Attachment Ring
Y
Y
Camera Adjustment
15 VFK1164TCM01 Collimator Set (Infinity Lens)
Y
Y
Camera Adjustment
16 VFK1345
CC Filter Holder
Y
Y
Camera Adjustment
17 VFK1346
Step
Down
Ring
Y
Y Camera
Adjustment
18 VFK1659
Step-Up Ring (43mm-49mm)
Y
Y
Camera Adjustment
19 VFK1660
Step-Up Ring (49mm-62mm)
Y
Y
Camera Adjustment
20 VFK1341
CC Filter (LB40)
Y
N
Camera Adjustment
21 VFK1342
CC Filter (LB80)
N
Y
Camera Adjustment
22 VFK1347
CC Filter (LB120)
Y
Y
Camera Adjustment
23 VFK1884
CC Filter (LBA2)
Y
Y
Camera Adjustment
24 VFK1888
CC Filter (LBB6)
Y
Y
Camera Adjustment
NOTE 4
25 VFK1885
CC Filter (LBB2)
Y
N
Camera Adjustment
26 VFK1886
CC Filter (CC C10)
N
Y
Camera Adjustment
27 VFK1887
CC Filter (CC C20)
N
Y
Camera Adjustment
28 VFK1409A
Measuring
Board
Y
Y LISTA
Adjustment
NOTE 5
29 VFK1233
Mech. Neutral Plate
Y
Y
Mechanical Maintenance
30 VFK1266
Gear Driver
Y
Y
Mechanical Maintenance
31 VFK1149B
Post Driver
Y
Y
Tape Post Height Adjustment
32 VFK1151A
Nut Driver (2.5mm)
Y
Y
Tape Post Height Adjustment
33 VFK1810
LISTA Measuring Board
Y
Y
LISTA Adjustment
NOTE 5
34 VFK1186
LISTA
Cable
Y
Y LISTA
Adjustment
35 MOR265
Morlytone Grease (For Metal)
Y
Y
Mechanical Part Replacement
36 VFK1300
A/D Converter Board
Y
Y
LISTA Adjustment
NOTE:
1. VFK1811B can be use for AG-DVX100 and AG-DVC80 EVR adjustment.
2. VFK1840A can be use for AG-DVX100 and AG-DVC180 EVR adjustment.
3. If you already have VFK1309, you can be modified to VFK1309A. (Refer to item “1-1. Modification procedure of VFK1309”
1. VFK1811B can be use for AG-DVX100 and AG-DVC80 EVR adjustment.
2. VFK1840A can be use for AG-DVX100 and AG-DVC180 EVR adjustment.
3. If you already have VFK1309, you can be modified to VFK1309A. (Refer to item “1-1. Modification procedure of VFK1309”
in section 4.)
4. The LBB6 is the compatible article of 80D. The cc filter 80D is made by Kodak, which was introduced with the
AG-DVX100/DVC80/DVC180 service manual. Being supplying LBB6(VFK1888) as service tool, which is made from Fuji
film, either can be used LBB6 and 80D for White Balance (5100K) adjustment.
film, either can be used LBB6 and 80D for White Balance (5100K) adjustment.
5.
If you already have VFK1409S, it can be use to LISTA adjustment with VFK1810 instead of VFK1409A. (Refer to item
“1-6-1. Connection of LISTA Adjustment system” in section 3.)