9-3. EVF Pedestal Level Adjustment
1. Connect the oscilloscope to “VCC9” on the VFK1308P.
2. Open the “EVF adjustment menu”.
3. Select “3. Pedestal Level adjustment” in the EVF adjustment menu, and then press the “Enter” key.
4. Adjust the differential amplitude both 10 step-level (portion “V” in figure) to become 3.35±0.1V as shown in
2. Open the “EVF adjustment menu”.
3. Select “3. Pedestal Level adjustment” in the EVF adjustment menu, and then press the “Enter” key.
4. Adjust the differential amplitude both 10 step-level (portion “V” in figure) to become 3.35±0.1V as shown in
figure.
Note:
1) Level (V) can be adjusted by press arrow keys on keyboard.
2) Waveform (figure) can be displayed by press F2 key.
5. When adjustment is finished, press ENTER key to adjusted data write to EEPROM.
1) Level (V) can be adjusted by press arrow keys on keyboard.
2) Waveform (figure) can be displayed by press F2 key.
5. When adjustment is finished, press ENTER key to adjusted data write to EEPROM.