PT-VZ575N, PT-VZ575ND, PT-VZ575NT, PT-VW535N, PT-VW535ND, PT-VW535NT, PT-VX605N, PT-VX605ND, PT-VX605NT (serv.man5) - Panasonic Projector Service Manual (repair manual). Page 30

Read Panasonic PT-VZ575N / PT-VZ575ND / PT-VZ575NT / PT-VW535N / PT-VW535ND / PT-VW535NT / PT-VX605N / PT-VX605ND / PT-VX605NT (serv.man5) Service Manual online

INF-22
SECTION 1 SERVICE INFORMATION
5. 3. 5. Air filter maintenance
Perform maintenance of the air filter in the following case.
•  The air filter is clogged with dust, causing the filter replacement message to appear on the screen.
Attention
• Make sure to turn off the power before performing maintenance on the air filter unit.
•  Make sure that the projector is stable, and perform the maintenance in a safe place where the unit will not be damaged even 
if you drop the air filter unit.
• After replacing the air filter, reset the filter counter. Otherwise, “FILTER COUNTER has reached the set time.” will appear on
screen.
5. 3. 6. Replacement procedure for air filter unit
1) Remove the air filter cover. (Fig. 1)
  •  Open the air filter cover in the direction of the arrow and remove it.
2) Remove the air filter unit. (Fig.2)
  •  Hold the tab on the left side of the air filter unit and pull out in the direction of the arrow.
  •  After removing the air filter unit, remove foreign objects and dust from the air filter compartment and the projector’s air 
intake port if there are any.
3) Attach the unused air filter unit to the projector (Fig.3)
  •  Hold the air filter unit that the tab is in up-left side in the figure, put the right side in the figure first, and press the tab side 
until make a click sound.
  • Do not press any other part of the air filter unit except the frame during installation.
4) Attach the air filter cover to the projector.
 • Perform Step 1) in “Removing the air filter unit” in the reverse order
  • Make sure that the air filter cover is closed tightly.
5)  Connect the power plug, press the power button <v
/b> on the control panel or on the remote control to turn on 
the power.
6)  Press the <MENU> button to display the main menu, then press as to select [PROJECTOR SETUP].
7)  Press the <ENTER> button, press 
as to select [FILTER COUNTER].
8)  Press the <ENTER> button, press 
as to select [FILTER COUNTER RESET].
9)  Press the <ENTER> button.
 • [FILTER COUNTER RESET] confirmation message is displayed.
10)   Press  q w to select [OK], then press the <ENTER> button.
  • The filter usage time is [0] after reset.
Attention
•  When using the projector, be sure to attach the air filter unit. If it is not attached, the projector will suck in dirt and dust caus-
ing a malfunction.
• Do not put anything into the air vents. Doing so may result in malfunction of the projector.
• The air filter unit to be replaced should be an unused product
Note
• The replacement cycle of the air filter unit varies greatly depending on the usage environment.
Air filter cover
Fig. 1
Tab
Air filter unit
Fig. 2
Fig. 3
Tab
Air filter unit
Page of 114
Display

Click on the first or last page to see other PT-VZ575N / PT-VZ575ND / PT-VZ575NT / PT-VW535N / PT-VW535ND / PT-VW535NT / PT-VX605N / PT-VX605ND / PT-VX605NT (serv.man5) service manuals if exist.