PT-VZ575N, PT-VZ575ND, PT-VZ575NT, PT-VW535N, PT-VW535ND, PT-VW535NT, PT-VX605N, PT-VX605ND, PT-VX605NT (serv.man5) - Panasonic Projector Service Manual (repair manual). Page 28

Read Panasonic PT-VZ575N / PT-VZ575ND / PT-VZ575NT / PT-VW535N / PT-VW535ND / PT-VW535NT / PT-VX605N / PT-VX605ND / PT-VX605NT (serv.man5) Service Manual online

INF-20
SECTION 1 SERVICE INFORMATION
5. 3. Replacement of consumable parts
[Attention] •  When replacing the consumable parts, please make sure that the power cable is disconnected from the outlet.
5. 3. 1. When to replace the lamp unit
The lamp unit is a consumable component. Since its brightness gradually decreases over time, it is necessary to replace the 
lamp unit regularly. The estimated duration before replacement is 5 000 hours, but the lamp may go off before reaching to 
5000 hours, depending on the characteristics of the individual lamp, usage conditions, and the installation environment. It is 
recommended that the Replacement Lamp Unit be prepared earlier.
On screen display
REPLACE LAMP
LAMP indicator
On screen display
REPLACE LAMP
LAMP indicator
Over 4 800 hours
The message is displayed for 30 seconds. Pressing 
any button on the control panel or remote control 
within 30 seconds will clear the message.
The indicator lights in red even during the 
standby mode.
Over 5 000 hours
The message remains displayed until you press any 
button.
If you continue to use the lamp unit after 5 000 hours has elapsed, the lamp turns off automatically after approximately 10 
minutes, as it may cause malfunction of the projector.
Note
• To predict when to replace the lamp, check the lamp runtime displayed at [STATUS] - [RUNTIME] in [PROJECTOR SETUP].
• 5 000 hours is only the target for replacement and not the warranty time.
5. 3. 2. Calculation formula of lamp runtime
The lamp runtime that is displayed in the [STATUS] is real time.
The following conversion is required to calculate the rough estimate for lamp replacement.
Formula for lamp replacement time (rough estimate)
= “Lamp runtime of [NORMAL]” + “Lamp runtime of [ECO]” × 5/7
5.2.5. Optical block type check
There are 2 types of optical block, named R-type and L-type.
When replacing the optical block, check the printed marker on the flat cable of the G-LCD panel and use the same type of the 
optical block. If not used the same type, you will find the color shading or wrong white balance picture on the screen. 
GL
GR
• GL => Use L-type optical block
• GR => Use R-type optical block
L-Type  optical block
R-Type optical block
G-LCD panel
Page of 114
Display

Click on the first or last page to see other PT-VZ575N / PT-VZ575ND / PT-VZ575NT / PT-VW535N / PT-VW535ND / PT-VW535NT / PT-VX605N / PT-VX605ND / PT-VX605NT (serv.man5) service manuals if exist.