PT-VZ575N, PT-VZ575ND, PT-VZ575NT, PT-VW535N, PT-VW535ND, PT-VW535NT, PT-VX605N, PT-VX605ND, PT-VX605NT (serv.man3) - Panasonic Projector Service Manual (repair manual). Page 24

Read Panasonic PT-VZ575N / PT-VZ575ND / PT-VZ575NT / PT-VW535N / PT-VW535ND / PT-VW535NT / PT-VX605N / PT-VX605ND / PT-VX605NT (serv.man3) Service Manual online

INF-16
SECTION 1 SERVICE INFORMATION
4. 2. 2. When Web control administrator rights password is set (Protect mode)
4. 2. 2. 1. Connecting
1.  Obtain the IP address and port number (Initial setting value = 1024) of the projector and request for a connection to the 
projector.
  You can obtain both the IP address and the port number from the menu screen of the projector.
 - IP address  : Obtain from the main menu → [NETWORK/USB] → [STATUS]
 - Port number  : Obtain from the WEB control → [Detailed set up] → [Command port set up] page
2. Check the response from the projector
 - Response data
Data section
Blank
Mode
Blank
Random number section
Termination symbol
"NTCONTROL"
(ASCII string)
' '
0x20
'1'
0x31
' '
0x20
"zzzzzzz"
(ASCII code hexadecimal number)
(CR)
0x0d
9 bytes
1 byte
1 byte
1 byte
8 bytes
1 byte
Mode: 1 = Protect mode
3. Generate a 32-byte hash value from the following data using MD5 algorithm.
 "xxxxxx:yyyyy:zzzzzzz"
xxxxxx
Administrator rights user name for Web control (default user name is “admin1”)
yyyyy
Password of above administrator rights user (default password is “panasonic”)
zzzzzzz
8-byte random number obtained in Step 2)
 
: colon : Separator
4. 2. 2. 2. Command transmission method
Transmit using the following command formats.
  Transmitted date
Header
Data section
Termination symbol
Hash value
(4. 2. 2. 1. -3)
'0'
0x30
'0'
0x30
Control command
(ASCII string)
(CR)
0x0d
32 bytes
1 byte
1 byte
Undefined length
1 byte
 Received data
Header
Data section
Termination symbol
'0'
0x30
'0'
0x30
Control command
(ASCII string)
(CR)
0x0d
1 byte
1 byte
Undefined length
1 byte
  Error response
Error message
Termination symbol
“ERR1”
Undefined control command
“ERR2”
Out of parameter range
“ERR3”
Busy state or no-acceptable period
“ERR4”
Timeout or no-acceptable period
“ERR5”
Wrong data length
“ERRA”
Password mismatch
(CR)
0x0d
4 bytes
1 byte
  Example: Query Power "QPW"
  1. Connects to the projector
   
IP = 192.168.0.8  
port = 1024
 2. Receives a response
   Response = "NTCONTROL 1 1aa6c14e" + (CR)
   
"1aa6c14e" = 8 bytes random characters
  3. Generates a hash value (message digest) from "admin1:panasonic:1aa6c14e" by using the MD5 algorithm.
   
"admin1" = Administrator authority user-name
   
"panasonic" = Password corresponding to "admin1"
   
Hash value = "01466bc27ed8c0b7e607471580c55953"
  4. Transmits the command
   Transmission data = "01466bc27ed8c0b7e607471580c5595300QPW" + (CR)
 5. Receives a response.
   Reception data = "00000" + (CR)
  6. Disconnects the connection with the projector.
Page of 113
Display

Click on the first or last page to see other PT-VZ575N / PT-VZ575ND / PT-VZ575NT / PT-VW535N / PT-VW535ND / PT-VW535NT / PT-VX605N / PT-VX605ND / PT-VX605NT (serv.man3) service manuals if exist.