INF-16
SECTION 1 SERVICE INFORMATION
<TW371R>
4. 2. Shutdown system
This projector provides the shutdown function to set into the standby mode immediately for product safety when the projector 
has the fan operation error or lamp lightning error. 
LED indication status
Shutdown detection
Probable cause
OSD warning
Not lighting or flashing
Power supply block
Fuse : Rated 6.3A
Blown out of fuse
(with another reason)
Thermal switch 
      Over 120ºC
Blown out of thermal fuse (with another 
reason) 
Check usage environment
ON(G)/STANDBY(R) LED 
blinks in orange
WARNING LED blinks 
in red
Lamp cover switch 
       Shutdown immediately if 
switch is OFF
Lamp cover is not installed securely
Lamp igniting error
Lamp error/burning
--
ON(G)/STANDBY(R) LED 
blinks in orange
WARNING LED is Off
Intake air temperature sensor
Intake air temperature error 
      Filter clogging 
      High temperature of environment 
      Ventilation holes are blocked
      Sensor error (IC1902)
Internal temperature sensor 
A(Panel)
Internal temperature sensor A error 
      Filter clogging 
      High temperature of environment 
      Ventilation holes are blocked
      Sensor error (IC1002)
Internal temperature sensor B(Lamp)
Internal temperature sensor B error 
      Filter clogging 
      High temperature of environment 
      Ventilation holes are blocked
      Sensor error (IC1003)
ON(G)/STANDBY(R) LED 
lights in orange
WARNING LED is off
Each FAN LOCK signal 
      No signal
FAN A (FN3001/FN3002)
Connector disconnection
Fan rotation error
Each FAN LOCK signal 
      No signal
FAN B (FN3003/FN3004)
Connector disconnection
Fan rotation error
Each FAN LOCK signal 
      No signal
FAN C (FN3005)
Connector disconnection
Fan rotation error
Detects Power error signal "P-FAIL". Internal power supply line error
ON(G)/STANDBY(R) LED 
lights in orange
WARNING LED lights 
in red
Iris operation error
Iris unit error
Connector disconnection
ON(G)/STANDBY(R) LED 
lights in green 
WARNING LED blinks 
in red
Lamp runtime
      Over 22 000 hours (It will auto-
matically shutoff in 10 min.)
Lamp runtime is over
Indicate lamp replacing icon