PT-RZ770, PT-RW730, PT-RZ660, PT-RW620 (serv.man4) - Panasonic Projector Service Manual (repair manual). Page 26

Read Panasonic PT-RZ770 / PT-RW730 / PT-RZ660 / PT-RW620 (serv.man4) Service Manual online

INF-14
SECTION 1 SERVICE INFORMATION
< RZ770/RW730/RZ660/RW620 >
 8. POWER OFF MESSAGE
  • Operation setting of shutter at standby operation.
    - SHUTTER KEEP:  When pushing the standby key while the shutter mode is on, the projector keeps the shutter mode 
on and sets into standby mode.
    - SHUTTER OPEN:   When pushing the standby key while the shutter mode is on, the projector opens the shutter and 
displays the "Power OFF confirmation message". (Default setting)
 9. ERROR OSD
  • Enables to display the error information of the LIGHT indicators on the screen.
    (It is useful when using the projector with rear projection mode)
    - ON : "LD1\LD2 ERROR" is displayed on the screen  if the lighting error occurs. 
            (It will disappear when any of the control buttons is pressed.)
    - OFF : No message is displayed on the screen if the lighting error occurs. (Default setting)
 10. MODEL
  • This setting is necessary when the A-P.C. Board is replaced with new one.
    * If you can copy EEPROM data from old A-P.C. Board, this setting is unnecessary.
    * This model setting is effective after power restart.
 11. LIGHT SELECT
  •  Select the LD units to turn on. Press the [ENTER] key to switch.
    - ALL : All LD blocks will light.  (Default)
    - LIGHT1 : LD1 block will light. 
    - LIGHT2 : LD2 block will light.
  • To return ALL When turn off the power.
 12. MUTE TIME OFFSET
  •  Set the extension of black mute time.
   It hides the input switching noise.
    - DISABLE : Does not extend the mute time.  (Default)
    - 0.5s : Mute time will be extended 0.5 seconds. 
    - 5.0s : Mute time will be extended 5.0 seconds.
 13. EDID 48HZ SETTING
  • Add a [48Hz] in vertical scan frequency to user setting of EDID.
   (When resolution is [1920x1080p] or [1920x1200p].)
    - OFF : 48Hz vertical scanning frequency is not added.  (Default)
    - ON : Vertical scanning frequency 48Hz can be selected. 
 14. INDICATOR SETTING
  • Set this when you want to turn off the indicator LED.
    [INDICATOR MODE]
    - NORMAL : The indicator maintains lighting (Default)
    - OFF : The indicator will be forcibly turned off.
    - TIMEOUT : The indicator turns off when no operation is taken for a certain time.
    [NO ACTIVITY TIME]
    Setup the time to turn off when INDICATOR MODE setting is TIMEOUT.
    You can set the time up to 15 minutes in 1 minute. (default setting is 15 MIN.)
    *If INDICATOR MODE setting is NORMAL or OFF, this will be grayed out.
    [INTERLOCKED 7SEG DISPLAY]
    Set this when you want to turn off the Self-diagnosis display (7SEG) on the control panel.
    - ON : Self-diagnosis indication will be linked with setting of INDICATOR MODE. (Default)
    - OFF : Self-diagnosis indication maintains lighting not linking with the setting of INDICATOR MODE.
    *If INDICATOR MODE setting is NORMAL, this will be grayed out.