PT-RZ770, PT-RW730, PT-RZ660, PT-RW620 (serv.man4) - Panasonic Projector Service Manual (repair manual). Page 25

Read Panasonic PT-RZ770 / PT-RW730 / PT-RZ660 / PT-RW620 (serv.man4) Service Manual online

INF-13
SECTION 1 SERVICE INFORMATION
< RZ770/RW730/RZ660/RW620 >
  (1) --- Projector type (Model No.) 
  (2) --- Projector serial number
  (3) --- Main microprocessor firmware version
  (4) --- Sub microprocessor firmware version
  (5) --- DIGITAL LINK firmware version
  (6) --- Formatter firmware version
  (7) --- FPGA firmware version (FPGA1/FPGA2)
  (8) --- LD driver firmware version
  (9) --- LD sub microprocessor firmware version
(10) --- Status of EMULATE setting
(11) --- Intake air temperature (Celsius/Fahrenheit)
(12) --- DMD temperature (Celsius/Fahrenheit)
(13) --- Exhaust air temperature (Celsius/Fahrenheit)
(14) --- LD1 temperature (Celsius)
(15) --- LD2 temperature (Celsius)
(16) --- LD1 check (1: normal / 0:stop)
(17) --- LD2 check (1: normal / 0:stop)               
(18) --- Fans control check (1: normal / 0: abnormal)
(19) --- Luminance sensor check (Detected value:Red/Green/Blue/Yellow)
(20) --- Atmospheric pressure sensor check (hPa/Celsius)
(21) --- Angle sensor check (Horizontal angle/Vertical angle)
f
 The following information is available for Asian model only.
(22) --- Communication status of the WL-P.C.Board
         - YES : Communication good
         - NO : Communication error (faulty or disconnected)
(23) --- Firmware version of IC on the WL-P.C.Board
(24) --- Usage environment information
         - Applicable country Information/Nonapplicable country Information
(25) --- Functional restriction setting status
         - YES : Function restriction has been canceled
         - NO : Function restriction has been enabled
(26) --- Function restriction countdown
         - Count of communication error/Count of environmental error
         - Count is decreased when an error is detected, and become restricted with counter " 0 ". (Maximum 30)
LD2 LD3
LD1
LD2 LD3
LD1
RADIA
TOR3 
PW1 
PW2
POWER
LD DRIVER
 EXHAUST3
DMD
EXHAUST1
EXHAUST2
RADIA
TOR2
RADIA
TOR1
PUMP1
PUMP2
* RZ660/RW620 are not mounted with PW1/PW2 fans, but  display will be "1".
 4. AUTO INDEX CALIBRATION
  • When replaced the phosphor wheel or color wheel, perform automatic adjustment of each wheel rotational phase.
    * Please refer to SECTION 3 (Adjustments) for the procedure.
 5. PW1 INDEX
 6. PW2 INDEX     
• 
Make the rotation phase adjustment of the wheels individually.
 7. CW INDEX 
 (Do not change the setting, usually.)
Page of 125
Display