PT-RZ470U, PT-RZ470E, PT-RZ470EA, PT-RW430U, PT-RW430E, PT-RW430EA (serv.man5) - Panasonic Projector Service Manual (repair manual). Page 8

Read Panasonic PT-RZ470U / PT-RZ470E / PT-RZ470EA / PT-RW430U / PT-RW430E / PT-RW430EA (serv.man5) Service Manual online

INF - 8
  2. SELF CHECK
・ Each self check item is displayed.
SELF CHECK
MAIN : 1.00.00   SUB : 1.00.00
Main, Sub microprocessor software version
NETWORK : 1.00.00   FPGA : 0x2A
Network and FPGA software version
BALLAST : 230  DIGITAL LINK : 1.30.33.1
BALLAST and DIGITAL LINK software version
EMULATE : DEFAULT
Setting and Version of EMULATE
OK
INTR.   026/224
Internal air temperature check (Celsius/Fahrenheit)
OK
INTK.   041/151
Intake air temperature check (Celsius/Fahrenheit)
OK
DMD.    054/104
DMD temperature check (Celsius/Fahrenheit)
OK
TEMP_R  036/101
LED-R temperature check (Celsius/Fahrenheit)
OK
TEMP_G  036/101
LD unit temperature check (Celsius/Fahrenheit)
OK
TEMP-B  036/101
LED-B temperature check (Celsius/Fahrenheit)
OK
WIND.   075/054/+5
Airflow sensor check (Sensor, AD conversion, Correction value)
OK
LIGHT   200h30m / 1  ON
Light source check (lighting accumulative time, number of times
OK
FAN     1111 11
the replacement, ON-OFF)
OK
PHOSPHOR WHEEL
Fan check (1:Normal/0: Abnormal)
From the left, LD-G, LED-R, LED-B, DMD, EXHAUST, DRIVER
Phosphor wheel check
  3. MODEL
・ Set this when the A-P.C.Board is replaced.
* If you can copy EEPROM data from the old A-P.C.Board, this setting is unnecessary.
* This model setting is changed after power restart.
  4. CLOG SENSOR CALIBRATION
・Calibrate the clogging sensor circuit.
  Execute this after EEPROM(IC1405)/A-P.C.Board or Airflow sensor (M3-P.C.Board) is replaced.
* Refer to the "SECTION3 (ADJUSTMENT PROCEDURE)" about method.
  5. DVI SELECT COMMAND
・Setting for DVI-I input terminal
DVI : Functions as a terminal for DVI input.
(When this item is selected, this terminal can be selected to Digital or Analog with DISPLAY OPTION menu.)
COMPUTER2 : Functions as a terminal for COMPUTER2 input. (Analog mode only.)
  6. OSD SIZE (DZ470 only)
Set the on-screen display size.
    3. 3. 2. Additional function of each menu
  1. "POSITION" menu
The following one item is added.
・DVI EQUALIZER
When noise contamination to DVI input caused by long cable or external device, set this item so that the 
noise decreases.
  2. "ADVANCED" menu.
The following two items are added.
・FRAME LOCK
Set this item when moving picture is disturbed with RGB input.
・EB TESTPATTERN (to "EDGE BLENDING")
The test pattern for edge blending is projected.
OFF : Projecting the input signal.
1 - 7 : Projecting the internally generated test pattern.
* When the PICTURE MODE is set "DYNAMIC", it is  OFF.
* If any error occurs, font of "OK" becomes red.
Page of 28
Display