PT-RZ370U, PT-RZ370E, PT-RZ370EA, PT-RW330U, PT-RW330E, PT-RW330EA (serv.man5) - Panasonic Projector Service Manual (repair manual). Page 9

Read Panasonic PT-RZ370U / PT-RZ370E / PT-RZ370EA / PT-RW330U / PT-RW330E / PT-RW330EA (serv.man5) Service Manual online

INF - 9
    4. 1. 6. Basic format
The transmission from PC starts with STX, ID, Command, Parameter and EXT are sent in order.
Parameter is added depending on the control.
1. Basic control command (No parameter)
2. Basic control command (with Parameter)
3. Basic control command (with sub command)
4. Calculation
Direction of how to deal the indicated value by parameter
Direction
 
Set the value of indicated value by parameter.
 
Add the indicated value by parameter on current value.
5. Code
Direction of plus / minus for the indicated value by parameter
Direction
 
The value indicated by parameter is plus. ( If it is 0, set this.)
 
The value indicated by parameter is minus.
6. Parameter
Indicate the setting or adjustment value with right justification.( 0 is not suppressed.)
For example, indicate "00001" for the setting value "1".
7. ID for the basic commands
・This projector will respond to the computer only in the following cases.
Respond only when the transmitted ID is matched to this projector's ID.
RESPONSE(ID ALL) in RS232C settings of this projector is ON and the sent ID is ALL.
RESPONSE(ID GROUP) in RS232C settings of this projector is ON.
・Specifically, please refer to "Control Commands List"
8. Response of basic control commands
In accepted period
It depends on each command.
Out of accepted period or no command
Parameter or REMOTE 2 terminal is active
9. Note
If a command is transmitted after the light source starts illuminating, there may be a delay in response or the 
command may not be executed. Try sending or receiving any command after 60 seconds.
When transmitting multiple commands, be sure to wait until 0.5 seconds has elapsed after receiving the response
from the projector before sending the next command.
There is a case that it takes some time for responding because of internal processing.
Please set the timeout period to more than 10 seconds until the responses comes back.
1 byte
4 bytes
1 byte
45h
52h
Character
30h
32h
0
E
R
4
E
R
Separator
Parameter
Terminal symbol
(ETX)
1 byte
Sub
d
Calculation
Command
Character
3 bytes
1 byte
Hexadecimal
02h
45h
0
1
31h
34h
Command
(Semi colon)
Undefined length
03h
Code
Hexadecimal
02h
2
52h
Hedder
Command
30h
Terminal symbol
STX)
(ETX)
1 byte
3 bytes
1 byte
1 byte
Separator
STX)
(Colon)
Hedder
Hedder
ID
Separator
(Colon)
1 byte
4
1 byte
4 bytes
1 byte
3 bytes
(ETX)
1 byte
5 bytes
1 byte
+
-
Code
=
_( underbar)
03h
34h
ID
Separator
(Semi colon)
ID
4 bytes
Separator
(Semi colon)
5 bytes
1 byte
Code
STX)
Parameter
Terminal symbol
Page of 26
Display