Read Panasonic PT-RZ21KE / PT-RS20K Service Manual online
INF-12
SECTION 1 SERVICE INFORMATION
< RZ21K / RS20K >
㉚
– Device check (OK: Normal, NG: abnormal)
㉓ --- Fan [1] check (1: normal / 0: abnormal)
㉔ --- Fan [2] check (1: normal / 0: abnormal)
㉕ --- Luminance sensor check (detected value)
㉖ --- Luminance sensor check (initial value)
㉗ --- Atmospheric pressure sensor check (hPa/Celsius)
㉘ --- Angle sensor check (Horizontal angle / Vertical angle)
㉙ --- Shutter control check
㉔ --- Fan [2] check (1: normal / 0: abnormal)
㉕ --- Luminance sensor check (detected value)
㉖ --- Luminance sensor check (initial value)
㉗ --- Atmospheric pressure sensor check (hPa/Celsius)
㉘ --- Angle sensor check (Horizontal angle / Vertical angle)
㉙ --- Shutter control check
(Opening and shutting times [Failure times])
SELF CHECK
OK : FAN[1] 1111 1111 1111 1111 1111
OK : FAN[2] 1111 1
OK : PHOTO Y 123456.7(R=+123/G=+123/B=+123)
3/3
OK : PHOTO INIT
OK : ATM 1234/567
OK : ANGLE H -123.4/ V +123.4
OK : SHUTTER 65535 [ 0]
q�w CHANGE
DEVICE CHECK : OK
Sensor
PCB
Ref No.
Luminance
M3
SN1401
Atmospheric pressure
RM
IC1501
Angle
A
IC3751
• Items
⑮
to
㉙
indicates the status of "NG" or "OK". If the "NG" indicates in red, the projector has an abnormal-
ity now. If the "OK" indicates in red, the projector had an abnormality in the past and operates normally now.
• To clear the error status, press the [MENU] key in the SELF CHECK mode, the confirmation window will ap-
pear and select [OK] to clear.
• This must be done after finishing the repair or maintenance.
CLEAR ERROR INFOMATION?
OK
CANCEL
w
How to read the status of light source
㉑
--- LD1 check (1: normal / 0: abnormal / *: intentional Off)
㉒
--- LD2 check (1: normal / 0: abnormal / *: intentional Off)
LD1-1 --- LD1-2 --- LD1-3 --- LD1-4 --- LD1-5 --- LD1-6 ---
OK : LD1 1 1 1 1 1 1
LD2-1 --- LD2-2 --- LD2-3 --- LD2-4 --- LD2-5 --- LD2-6 ---
OK : LD2 1 1 1 1 1 1
• Intentional Off
If one of the laser device has an open failure for blue or yellow light, the projector cuts off the other laser
device intentionally to maintain the proper white balance. It will return the normal operation when the LD
unit which has an open failure device actually is replaced with new one.