ADJ-17
SECTION 3 ADJUSTMENTS
< RZ21K / RS20K >
8. Completion screen is displayed, and click the [OK] button.
Confirm the runtime is set to 0h.
[Display example] The open failure occurs on LD1-3
1.10. LD unit status reset
f
The error information is stored in the memory if the projector turn on in the state of disconnecting of LD unit connectors.
In this case, to clear the error status by using the LDResetTool. (Runtime is not reset.)
1. Start the LDReset Tool with the same procedure of "1. 9. LD unit runtime reset".
Click the [Get Information] button to display the each LD unit status.
2. A confirmation window will be displayed when click the [LD Status Reset] button.
Then click the [OK] button.
Display example of LD1-3 reset
• After completing the reset, turn off the main power, turn on the power again, and check that runtime with
the [STATUS] screen.