Read Panasonic PT-RQ13K (serv.man2) Service Manual online
INF-15
SECTION 1 SERVICE INFORMATION
< RQ13K >
4. POWER OFF MESSAGE
• Setting of the shutter function with standby operation
- SHUTTER KEEP: When pushing the standby key while the shutter mode is on, the projector keeps the shutter mode on
and sets into standby mode.
- SHUTTER OPEN: When pushing the standby key while the shutter mode is on, the projector opens the shutter and displays
the "Power OFF confirmation message". (Default setting)
5. ERROR OSD
• Enables to display the error information of the LIGHT indicators on the screen (It is useful when using the projector with
rear projection mode)
- ON : "LIGHT1\LIGHT2 ERROR" is displayed on the screen if the lighting error occurs. (It will disappear when any of the
control buttons is pressed.)
- OFF : No message is displayed on the screen if the lighting error occurs. (Default setting)
6. ELECTRIC CONVERGENCE
• Aligns the convergence electrically. refer to chapter SECTION 3 (Adjustments)
7. MECHANICAL CONVERGENCE
• Aligns the convergence mechanically. refer to chapter SECTION 3 (Adjustments)
8. MODEL
This setting is necessary when the A-P.C. Board is replaced with new one.
• If you can copy EEPROM data from old A-P.C. Board, this setting is unnecessary.
• This model setting is effective after power restart.
9. CLOG SENSOR CALIBRATION
• This is to calibrate the clog sensor circuit. This calibration is necessary when the [A]-P.C Board, EEPROM (IC3711/IC3712)
or [M2]- P.C. Board is replaced.
• Refer to the chapter SECTION 3 (Adjustments) for the procedure.
10. SMOKE FILTER DISPLAY
• Setting of the warning display (self-diagnosis display "U75") at the time of smoked cut-off filter use.
- ON : Warning is displayed. (Default)
- OFF : Warning is not displayed.
11. LIGHT SELECT
• Select the LD to turn on. Press the [ENTER] key to switch.
– ALL : Both of LD1/LD2 turn on (Default)
– LD1 : LD1 turns on
– LD2 : LD2 turns on
• The selection will be reset to "ALL" after turning off the projector.
(30)
- Fans control check (1: normal / 0: abnormal)
(31)
- Luminance sensor check (detected value)
(32)
- Atmospheric pressure sensor check (hpa/Celsius)
(33)
- Angle sensor check (Horizontal angle / Vertical angle)
(34)
- Shutter control check (Opening and shutting times [Failure times])
2.