Read Panasonic PT-RCQ10 / PT-RCQ80 (serv.man3) Service Manual online
INF-15
SECTION 1 SERVICE INFORMATION
< RCQ10 / RCQ80 >
4. AUTO INDEX CALIBRATION
• When replaced the phosphor wheel or color wheel, perform automatic adjustment of each wheel rotational phase.
* Please refer to SECTION 3 (Adjustments) for the procedure.
5. PW1 INDEX
6. PW2 INDEX
7. CW INDEX
6. PW2 INDEX
7. CW INDEX
8. POWER OFF MESSAGE
• Operation setting of shutter at standby operation.
- SHUTTER KEEP: When pushing the standby key while the shutter mode is on, the projector keeps the shutter mode
on and sets into standby mode.
- SHUTTER OPEN: When pushing the standby key while the shutter mode is on, the projector opens the shutter and
displays the "Power OFF confirmation message". (Default setting)
9. ERROR OSD
• Enables to display the error information of the LIGHT indicators on the screen.
(It is useful when using the projector with rear projection mode)
- ON : "LD1/LD2 ERROR" is displayed on the screen if the lighting error occurs.
(It will disappear when any of the control buttons is pressed.)
- OFF : No message is displayed on the screen if the lighting error occurs. (Default setting)
10. MODEL
• Set the model and destination of this projector after replacing the A-PCB.
* This model setting is effective after main power restart.
11. LIGHT ADJUST
• Used when checking the light source. (It is not normally used.)
[LIGHT SELECT]
• You can setup the light source to be lit.
- ALL: All lighting blocks (LD1 / LD2) will light up. (Default setting)
- LD1: Only the lower side of the lighting block (LD1) will be lit.
- LD 2: Only the upper side of the lighting block (LD2) is lit.
* After selection, press the <ENTER> button to switch.
* When the power is turned off , it returns to "ALL". (Default setting)
[TEST PATTERN]
• Display test pattern (all white) for optical adjustment. (For factory adjustment)
12. LIGHT RUNTIME RESET
• When replacing the LD unit with a new one, reset the LD runtime.
This resetting is effective after main power restart.
* Please refer to SECTION 3 (Adjustments) for the procedure.
13. MUTE TIME OFFSET
• Set the extension of black mute time.
It hides the input switching noise.
- DISABLE : Does not extend the mute time. (Default setting)
- 0.5s --- 5.0s : Extension of mute time can be set in 0.5 second steps.
14. INDICATOR SETTING
• Set this when you want to turn off the indicator LED.
[INDICATOR MODE]
- NORMAL : Turn on or off the indicator LED according to the projector status.(Default setting)
- OFF : The indicator will be forcibly turned off.
- TIMEOUT : The indicator turns off when no operation is taken for a setting time.
[NO ACTIVITY TIME]
Setup the time to turn off when INDICATOR MODE setting is TIMEOUT.
You can set the time up to 15 minutes with 1 minute step. (default setting is 15 MIN.)
*If INDICATOR MODE setting is NORMAL or OFF, this will be grayed out.
• Make the rotation phase adjustment of the wheels individually.
(Do not change the setting, usually.)
Click on the first or last page to see other PT-RCQ10 / PT-RCQ80 (serv.man3) service manuals if exist.