Read Panasonic PT-MZ770 / PT-MW730 (serv.man3) Service Manual online
ADJ-7
SECTION 3 ADJUSTMENTS
<MZ770/MW730>
1. 5. Panel type setting
1. 5. 1. Preparation
Before taking this setting, confirm the type of optical block (L-Type or
R-Type) according to the item "Optical block type check" in the sec-
tion 1 "Service Information".
1. 5. 2. Setting procedure
1. Enter the service mode (EXTRA OPTION) and select [PANEL
TYPE SETTING].
2. Change the panel type to [L] or [R] with [
t
] [
u
] buttons to match
the optical block type which is installed on the projector.
L: L-Type
R: R-Type
EXTRA OPTION
1/2
CMS
SELF CHECK
SELF CHECK
SHUTTER KEEP
ON
OFF
L
NORMAL
FLICKER ADJUST
POWER OFF MESSAGE
ERROR OSD
MODEL
POWER OFF MESSAGE
ERROR OSD
MODEL
PANEL TYPE SETTING
PANEL DRIVE SETTING
KEYSTONE CALIBRATION
KEYSTONE CALIBRATION
RGB PIXEL ADJUST
GHOST FB CALIBRATION
CLOG SENSOR CALIBRATION
MENU SELECT
CHANGE
ENTER
1. 6. Flicker adjustment
1. Enter the service mode (EXTRA OPTION) and select [FLICKER
ADJUST] and press [ENTER] button to enter the flicker adjustment
mode.
2. The whole red raster pattern will displayed on the screen when
entering the adjustment mode.
3. Adjust the flicker to be minimum with [
t
] [
u
] buttons.
4. Change another adjustment pattern with [
p
] [
q
] buttons and
repeat the step 3 above.
Projector provide 3 adjustment patterns "Red", "Green" and "Blue".
5. After finishing the adjustment, press [MENU] button to exit the
adjustment mode.
EXTRA OPTION
1/2
CMS
SELF CHECK
SELF CHECK
SHUTTER KEEP
ON
OFF
L
NORMAL
FLICKER ADJUST
POWER OFF MESSAGE
ERROR OSD
MODEL
PANEL TYPE SETTING
PANEL DRIVE SETTING
KEYSTONE CALIBRATION
ERROR OSD
MODEL
PANEL TYPE SETTING
PANEL DRIVE SETTING
KEYSTONE CALIBRATION
RGB PIXEL ADJUST
GHOST FB CALIBRATION
CLOG SENSOR CALIBRATION
MENU SELECT
CHANGE
ENTER
1. 7. Model setting
1. Enter the service mode (EXTRA OPTION) and select [MODEL]
and press [ENTER] button to enter the model setting mode.
2. Select the model of the projector with [
p
] [
q
] buttons and press
[ENTER] button.
3. After finishing the setting, press [MENU] button to exit the setting
mode.
EXTRA OPTION
1/2
CMS
SELF CHECK
SELF CHECK
SHUTTER KEEP
ON
OFF
L
NORMAL
FLICKER ADJUST
POWER OFF MESSAGE
ERROR OSD
POWER OFF MESSAGE
ERROR OSD
MODEL
PANEL TYPE SETTING
PANEL DRIVE SETTING
KEYSTONE CALIBRATION
PANEL DRIVE SETTING
KEYSTONE CALIBRATION
RGB PIXEL ADJUST
GHOST FB CALIBRATION
CLOG SENSOR CALIBRATION
MENU SELECT
CHANGE
ENTER
MODEL
WXGA :PT-MW730
WXGA :PT-MW730D
WXGA :PT-MW730J
WXGA :PT-MW730A
WXGA :PT-SMW73C
SELECT
SET
ENTER
MODEL
WUXGA :PT-MZ770
WUXGA :PT-MZ770D
WUXGA :PT-MZ770J
WUXGA :PT-MZ770A
WUXGA :PT-SMZ77C
SELECT
SET
ENTER
D
J
J
A
C
● In case of the Optical block replaced:
Confirm that the type of optical block and setting are matched.
● In case of A-PCB replaced:
After transferring the standard or original gamma/uniformity data,
Confirm that the type of optical block and setting are matched.
● In case of A-PCB replaced:
After transferring the standard or original gamma/uniformity data,
confirm that the type of optical block and setting are matched.
Click on the first or last page to see other PT-MZ770 / PT-MW730 (serv.man3) service manuals if exist.