Details: ④ There was a case that after Projector's power is turned ON, Lamp is turned ON even if 
Fan does not rotate.
(In this case, the Projector will be shut down after 30 seconds by fan error.)
Cause: ④ There was a case that Power ON control process does not operate correctly
when fan does not rotate.
Power ON control process has been changed.
Details: ⑤ There was a case that Input is not switched to 「NETWORK」 even if 「NETWORK」 input
is programmed by [SCHEDULE] function.
(This symptom does not occur other than 「NETWORK」 input.)
Cause: ⑤ There was a case that input switching process does not operate correctly
with 「NETWORK」 input.
Input switching process has been changed.
Details: ⑥ There was a case that after Projector's power is turned ON, 「NTP SYNCHRONIZATION」
function does not complete the synchronization to network under the following conditions.
(Conditions)
① Set 「NTP SYNCRONIZATION」 of [DATE AND TIME ] menu to ON.
② Turn OFF the Projector's power, and then turn it to ON again.
Cause: ⑥ By the timing of the communication process between Main microprocessor and
Network microcoprocessor at the time of Projector's power-up, there was a case that 
「NTP SYNCRONIZATION」 function can not be executed.
「NTP SYNCRONIZATION」 process has been changed.
Details: ⑦ There was a case that after Projector's power is turned ON, picture does not display
under the following conditions.
(Conditions)
① Select 「NETWORK」 input.
② Set [IN STANDBY MODE] of [AUDIO SETTING] menu to ON.
③ Turn OFF the Projector's power, and then turn it to ON again.
Cause: ⑦ There was a case that Audio signal detection does not operate correctly, 
if [IN STANDBY MODE] is set to ON in [NETWORK] input mode.
Audio signal detection process has been changed.
Remedy:
Please download the following firmware from the PASS website, and update them.
Main firmware version : Version 1.08
FPGA firmware version : Version 1.01