PT-FW300NTU, PT-FW300NTE, PT-FW300NTEA, PT-FW300U, PT-FW300E, PT-FW300EA, PT-F300NTU, PT-F300NTE, PT-F300NTEA, PT-F300U, PT-F300E, PT-F300EA - Panasonic Projector Service Manual (repair manual). Page 7

Read Panasonic PT-FW300NTU / PT-FW300NTE / PT-FW300NTEA / PT-FW300U / PT-FW300E / PT-FW300EA / PT-F300NTU / PT-F300NTE / PT-F300NTEA / PT-F300U / PT-F300E / PT-F300EA Service Manual online

Note:
     − 
− 
− 
− 
Do not change the setting when it is possible to receive normally.
Change the setting only when the image is not displayed normally because of the sync signal noise of connected
equipment.
     ·    
VGA60/480p
     − 
− 
− 
− 
AUTO: Switching RGB of VGA60 and 480p automatically
     − 
− 
− 
− 
VGA60: Inputting signals in 59.9Hz / VGA480
     − 
− 
− 
− 
480p: Inputting signals in RGB of 480p
     ·    
HPLL
When non-standard signal of VIDEO/S-VIDEO is inputted (VCR, VHD, etc.), horizontal synchronization might be disordered
according to connected equipment. In this case, set HPLL to OFF.
     ·    
EMULATE
witching the operation of RS-232C command to communicate with models other than FW300/F300 series
     − 
− 
− 
− 
DEFAULT: F100/FW100/F200/F300/FW300 series standard
     − 
− 
− 
− 
D3500: D3500
     − 
− 
− 
− 
D4000: D4000
     − 
− 
− 
− 
D/W5K series: D/DW5000 series
     − 
− 
− 
− 
L730: L730
     − 
− 
− 
− 
L780: L780
     − 
− 
− 
− 
L735: L735
     − 
− 
− 
− 
L785: L785
     − 
− 
− 
− 
LB/W80: LB75/LB80/LW 80
     − 
− 
− 
− 
OTHER: Models other than the above-mentioned (Consult your dealer or Authorized Service Center for details.)
     ·    
FILTER SETUP
Setting the operation of ACF according to the environment in use
     − 
− 
− 
− 
1: Crowded place (Restaurant, Public domain, etc.)
     − 
− 
− 
− 
2: Place where open air does not flow in so much
Note:
     − 
− 
− 
− 
Normally, set it to "2".
     ·    
ACF ROLL
Forwarding the ACF (Auto Cleaning Filter) compulsorily
     ·    
SELF CHECK
To enter the self-check mode
     ·    
TEST PATTERN
To display test patterns
     ·    
FLICKER ADJUST
To enter the flicker adjustment mode
3.3. Canceling EXT OPTION
Press "MENU" button on the main unit or remote control.
4 Self-Check Mode
This mode is used to narrow down the location of the failure.
4.1. Procedure to enter the self-check mode
Select "SELF CHECK" on "EXT OPTION" menu and press "ENTER" button on the main unit or remote control.
7
PT-FW300NTU / PT-FW300NTE / PT-FW300NTEA / PT-FW300U / PT-FW300E / PT-FW300EA / PT-F300NTU / PT-F300NTE / PT-F300NTEA / PT-F300U / PT-F300E / PT-F300EA
Page of 127
Display

Click on the first or last page to see other PT-FW300NTU / PT-FW300NTE / PT-FW300NTEA / PT-FW300U / PT-FW300E / PT-FW300EA / PT-F300NTU / PT-F300NTE / PT-F300NTEA / PT-F300U / PT-F300E / PT-F300EA service manuals if exist.