PT-EZ580, PT-EZ580L, PT-EZ580D, PT-EZ580LD, PT-EW640, PT-EW640L, PT-EW640D, PT-EW640LD, PT-EX610, PT-EX610L, PT-EX610D, PT-EX610LD - Panasonic Projector Service Manual (repair manual). Page 27

Read Panasonic PT-EZ580 / PT-EZ580L / PT-EZ580D / PT-EZ580LD / PT-EW640 / PT-EW640L / PT-EW640D / PT-EW640LD / PT-EX610 / PT-EX610L / PT-EX610D / PT-EX610LD Service Manual online

INF-19
SECTION 1 SERVICE INFORMATION
4. 2. 2. 2. Command transmission method
Transmit using the following command formats.
  Transmitted date
Header
Data section
Termination symbol
Hash value
(4. 2. 2. 1. -3)
'0'
0x30
'0'
0x30
Control command
(ASCII string)
(CR)
0x0d
32 bytes
1 byte
1 byte
Undefined length
1 byte
 Received data
Header
Data section
Termination symbol
'0'
0x30
'0'
0x30
Control command
(ASCII string)
(CR)
0x0d
1 bytes
1 byte
Undefined length
1 byte
  Error response
Error message
Termination symbol
“ERR1”
Undefined control command
“ERR2”
Out of parameter range
“ERR3”
Busy state or no-acceptable period
“ERR4”
Timeout or no-acceptable period
“ERR5”
Wrong data length
“ERRA”
Password mismatch
(CR)
0x0d
4 byte
1 byte
Example: Query Power "QPW"
  1. Connects to the projector
   
IP = 192.168.0.8  
port = 1024
 2. Receives a response
   Response = "NTCONTROL 1 1aa6c14e" + (CR)
   
"1aa6c14e" = 8 bytes random characters
 3. Generates a hash value (message digest) from "admin1:panasonic:1aa6c14e" by using the MD5 algorithm.
   
"admin1" = Administrator authority user-name
   
"panasonic" = Password corresponding to "admin1"
   
Hash value = "01466bc27ed8c0b7e607471580c55953"
  4. Transmits the command
   Transmission data = "01466bc27ed8c0b7e607471580c5595300QPW" + (CR)
 5. Receives a response.
   Reception data = "00000" + (CR)
  6. Disconnects the connection with the projector.