SECTION 1  SERVICE  INFORMATION
< DZ780/DW750/DX820 >
2. [POSITION] menu
f [DVI EQUALIZER] is added to a sub menu.
- When noise contamination to DVI input caused by long cable or external device, set this item so that the 
noise decreases. [AUTO/LOW/MID/HIGH]    
Usually, set to [AUTO].
3. [PROJECTOR SETUP] menu
f [DETAILED INFORMATION] is added to [BRIGHTNESS CONTROL STATUS] of sub menu [BRIGHTNESS CONTROL].
- Detailed information of BRIGHTNESS CONTROL can be checked.
f [EMULATE] is added to sub menu [RS232C], and following other company model items are added.
- MODE_HI
- MODE_NE
- MODE_EP
- MODE_SA
- MODE_SH
- MODE_MI
- MODE_SO
- MODE_CH
- OTHER
f The following items are added to the sub menu [STATUS].
1) Page 2
- VERTICAL TILT
Vertical angle
- HORIZONTAL TILT
Horizontal angle
2) Page 3
- DIGITAL LINK VERSION
DIGITAL LINK microprocessor software version
- FPGA VERSION
FPGA software version (FPGA1/FPGA2)
- DDP VERSION
Formatter microprocessor software version
- BALLAST VERSION
Ballast microprocessor software version (for LAMP1/LANP2)
- EMULATE
State of the EMULATE setting
- VERSION
Emulate version
3) Page 4
- LAMP1 ON
Number of times that the lamp1 was on,  [Failed number of times] 
- LAMP2 ON
Number of times that the lamp2 was on,  [Failed number of times] 
- SHUTTER
Number of times that the shutter was on and off,  [Failed number of times] 
4) Page 6
- MAIN VER.
Main microprocessor software version
- FPGA VER.
FPGA software version (FPGA1/FPGA2)
- BMP VER.
Bitmap data version
- ENG VER. ~CC VER.
Version of the each font data
 (English/Russian/Korean/Chinese/Japanese/Closed caption)
5) Page 7 
- TEMP(℃)
Intake air temperature (IN) / Optical module temperature (OPT) /
Exhaust air temperature (OUT)
- P. SENSOR
Luminance sensor detected value
- VOLT
Voltage of LAMP1 and LAMP2
- AIR FLOW
Air flow sensor detected value/AD conversion value,
Sensor correction value/AD conversion value
- FAN MODE
FAN control mode (LOW/MID/HIGH)
- CLOG
Fan rev up state due to clogging of air filter
(+0:NONE, +1:LEVEL1, +2:LEVEL2, +3:LEVEL3, Life extension:LIFE)
- DMD
DMD fan condition [Fan speed]
- LAMP1
Lamp1 fan condition [Fan speed]
- LAMP2
Lamp2 fan condition [Fan speed]
- EXHAUST1
Exhaust 1 fan condition [Fan speed]
- EXHAUST2
Exhaust 2 fan condition [Fan speed]
- CW
Color wheel fan condition [Fan speed]
- POWER
Power fan condition [Fan speed]
- BALLAST
Ballast fan condition [Fan speed]
- PUMP
Liquid cooling pump condition [Rotation speed]
- amt
Atmospheric pressure sensor detected value (hPa)
INF - 12