PT-DZ12000U, PT-DZ12000E, PT-D12000U, PT-D12000E, PT-DW100U, PT-DW100E (serv.man2) - Panasonic Projector Service Manual (repair manual). Page 10

Read Panasonic PT-DZ12000U / PT-DZ12000E / PT-D12000U / PT-D12000E / PT-DW100U / PT-DW100E (serv.man2) Service Manual online

(3)
Select SERVICE PASSWORD using the
or
buttons and
press the ENTER button.
The SERVICE PASSWORD screen will be displayed.
(4)
Input the password "0000" with the numeric buttons (0 to 9) of the
remote control unit and press the ENTER button.
Note:
     ·    
Asterisk (*) will appear for the password numbers.
(5)
When "USER MODE" is displayed, the resetting to the user mode is
completed.
4.3. Functions in Serviceman Mode
4.3.1. Additional Function for DYNAMIC IRIS in PICTURE menu
     ·    
AI WINDOW
Sets the APL detection area.
4.3.2. Additional Function for POSITION menu
     ·    
DVI EQUALIZER
If noise appears when DVI input, sets the value so that the noise decreases.
4.3.3. Additional Functions for ADVANCED MENU
     ·    
FRAME LOCK
When the picture is displayed by the input V-sync frequency, sets it to ON. However, there is a signal format that cannot be set
to ON.
     ·    
V MASK
If the picture falls into disorder when RGB1 or RGB2 input, sets the value so that the disorder decreases.
     ·    
PLL SETTING
If the picture falls into disorder when RGB1 or RGB2 input, sets VCO and the charge pump so that the disorder decreases.
Sets VCO and the charge pump.
4.3.4. Additional Function for CLAMP POSITION in ADVANCED MENU
     ·    
WIDTH
If the picture falls into disorder even if the clamp position is adjusted when RGB1 or RGB2 input, adjusts the value.
4.3.5. Additional Function for AUX SDI IN in DISPLAY OPTION menu
     ·    
XYZ TO RGB SETTING
     − 
− 
− 
− 
FACTORY SETTING: The Yxy value of FACTORY is used for original data of the XYZ to RGB conversion coefficient.
Default
     − 
− 
− 
− 
MEASURE: The Yxy value of MEASURE is used for original data of the XYZ to RGB conversion coefficient.
     − 
− 
− 
− 
Rec709: The Yxy value of Rec709 is used for original data of the XYZ to RGB conversion coefficient.
     − 
− 
− 
− 
DCI P3: The Yxy value of DCI P3 is used for original data of the XYZ to RGB conversion coefficient.
     ·    
XYZ TEST PATTERN
The following patterns can be selected.
10
PT-DZ12000U / PT-DZ12000E / PT-D12000U / PT-D12000E / PT-DW100U / PT-DW100E
Page of 127
Display

Click on the first or last page to see other PT-DZ12000U / PT-DZ12000E / PT-D12000U / PT-D12000E / PT-DW100U / PT-DW100E (serv.man2) service manuals if exist.