ET-YFB100G - Panasonic Projector Service Manual (repair manual). Page 14

Read Panasonic ET-YFB100G Service Manual online

  7. 3. Serial Number Setup
    7. 3. 1. Required equipments
1. PC :  Use it as adjustment use.
2. Communication cable : D-sub 9pin (male/emale  RS-232C straight)
3. Software : [Service YFB100.exe]Adjustment software is downloaded from the projector service homepage.
* Please prepare the projector and LAN cable corresponding for DIGITAL LINK.
    7. 3. 2. Preparation
1. Connect the RS-232C terminal of interface box and computer, with a RS-232C cable.
2. Connect the DIGITAL LINK terminal of interface box and projector, with a LAN cable.
    7. 3. 3. Setting method
1. Switching on the interface box and projector. (POWER indicator is lighted in green.)
2. Select the "BOX" in the "RS232C SELECT" of "EXT OPTION" menu. 
    (C* Please close another software before using the "Service software".
3. Start up service software [Service YFB100.exe] with a computer.
4. Select language and click the [ OK ] button.
5. 1) Select the Serial Port of the computer.
    2) Select a model number.
    3) Click the [ Data ] button.
6.  Click the [ Serial Number ] button.
7. Input the product serial number, and click the [ Send ] button.
Computer
Interface box
RS-232C cable (Streight)
LAN (CAT5e)
DIGITAL LINK compatible
projector
14
Page of 32
Display

Click on the first or last page to see other ET-YFB100G service manuals if exist.