FA-S280 - Panasonic Copying Equipment Service Manual (repair manual). Page 30

Read Panasonic FA-S280 Service Manual online

3-7
Maintenance
3.4.7
Sensor P Bracket Ass'y and CPU PCB
(1) Remove the sensor P bracket ass'y. (1 screw)
(2) Disconnect the cables of the sensors from the relay connectors.
Note: The  sensor P bracket ass'y incorporates the enter sensor and exit sensor.
When reassembling it, do not mis-connect the sensor cables. The wire
color of the sensor must match the harness color
 • Wire color of the enter sensor: Red, Blue and Black (2A)
 • Wire color of the exit sensor:
Red, White and Black (2B)
(3) Remove the four idler spring ass'ys. (1 screw each)
(4) Remove the sheet C/C. (4 screws)
(5) Remove the CPU PCB. (4 screws)
(6) Disconnect each connector from the CPU PCB.
Note: To reassemble the CPU PCB, tighten four screws with a torque of about 3
kg·f·cm. Do not apply excessive torque.
SV016
3
5
4
1
2B
2A
Page of 41
Display