FA-A888 - Panasonic Copying Equipment Service Manual (repair manual). Page 55

Read Panasonic FA-A888 Service Manual online

6-4
6.3 Adjustment
Height adjustment
Only required if the gap between the
platen glass and rubber spacer is over
0.5mm.
(See bottom figure)
a) Remove the top right cover of the
copier. (2 screws)
b) Remove the top left cover of the
copier. (2 screws)
c) Remove the original guide plate
of the copier. (3 screws)
(1) Remove the transport belt unit.
a) Open the ADF to the service
position.
(90 degrees)
b) Remove the 2 screws on the
upper frame. (See top figure)
c) Remove the transport belt unit.
(2) Place the transport belt unit on the
platen glass. (See the figure on the
left)
Note: Make sure to align the
magnet with the magnet
catches.
(3) Loosen the fixing screws. (4 screws)
(Left and right)
(4) Adjust the position of the magnets
so the gap between the platen glass
and the rubber spacer is less than
0.5mm.
(Right and left side)
(5) Reassemble in the reverse order.
1
Location
Shipping material /Procedure
Check
SU009
Transport belt unit
Fixing screw
(Left side)
Platen Glass
Rubber
spacer
Magnet
Magnet cartch
Fixing screw
(Right side)
Rubber spacer
Magnet
Magnet cartch
2
2
SV011
SV010
Page of 64
Display