TX-PR42UT30 - Panasonic Plasma Service Manual (repair manual). Page 25

Read Panasonic TX-PR42UT30 Service Manual online

25
8.18. Remove the K-Board
1. Remove the Glass holder bottom. (See section 8.17.)
2. Remove the claw (
×1 ).
3. Disconnect the connector (K1) and Remove the K-Board
from LED Panel.
8.19. Remove the V-Board
1. Remove the Glass holder bottom. (See section 8.17.)
2. Remove the screw (
×1 ).
3. Remove the claw (
×1 ).
4. Disconnect the connector (V14) and remove the V-Board
from the 3D emitter panel.
8.20. Replace the Plasma panel
Caution:
A new Plasma panel itself without Hanger metals is
fragile.
To avoid the damage to new Plasma panel, carry a new
Plasma panel taking hold of the Hanger metals after
assembling the Hanger metals and the Stand bracket.
1. Place a carton box packed a new Plasma panel on the
flat surface of the work bench.
2. Open a box and without taking a new Plasma panel;
Attach the C1-Board and the C2-Board, connect the flexi-
ble cables from the Plasma panel to the C1-Board and
the C2-Board, and fit the Flexible cable holders.
3. Attach the Hanger metals and the Stand bracket to the
new Plasma panel.
4. Place the Plasma panel on the servicing stand taking hold
of the Hanger metals.
5. Attach the Cabinet assy and each P.C.Board and so on,
to the new Plasma panel.
*When fitting the Cabinet assy, be careful not to allow any 
debris, dust or handling residue to remain between the 
Front glass and Plasma panel.
Page of 114
Display

Click on the first or last page to see other TX-PR42UT30 service manuals if exist.