TX-PR42S10 - Panasonic Plasma Service Manual (repair manual). Page 24

Read Panasonic TX-PR42S10 Service Manual online

24
6. Remove the screw (
×1 
) and remove the S-Board.
7.19. Remove the Front glass
1. Remove the Cabinet assy. (See section 7.17.)
2. Remove the S-Board. (See section 7.18.)
3. Remove the screws (
×5 ).
4. Remove the screws (
×4 ).
5. Remove the Glass holder side (L, R).
6. Remove the screws (
×7 ).
7. Remove the Glass holder top front.
8. Remove the Glass holder bottom front.
9. Remove the Front glass.
7.20. Remove the K-Board
1. Remove the Front glass. (See section 7.19.)
2. Remove the screw (
×2 ).
3. Remove the claw (
×1 ).
4. Disconnect the connector (K1) and remove the K-Board
from LED Panel.
7.21. Replace the plasma panel
Caution:
A new plasma panel itself without Hanger metals is
fragile.
To avoid the damage to new plasma panel, carry a new
plasma panel taking hold of the Hanger metals after
assembling the Hanger metals and the Stand brackets.
1. Place a carton box packed a new plasma panel on the flat
surface of the work bench.
2. Open a box and without taking a new plasma panel;
Attach the C1-Board and the C2-Board, connect the flexi-
ble cables from the plasma panel to the C1-Board and the
C2-Board, and fit the flexible cable holders.
3. Attach the Hanger metals and the Stand brackets to the
new plasma panel.
4. Place the plasma panel on the servicing stand taking hold
of the Hanger metals.
5. Attach the cabinet assy and each P.C.Board and so on, to
the new plasma panel.
*When fitting the cabinet assy, be careful not to allow any 
debris, dust or handling residue to remain between the 
front glass and plasma panel.
Page of 126