TH-R37PV8R - Panasonic Plasma Other Service Manuals (repair manual). Page 13

Read Panasonic TH-R37PV8R Other Service Manuals online

12
5.2.
Service tool mode
5.2.1.
How to access
1. Select [SRV-TOOL] in Service Mode.
2. Press [OK] button on the remote control.
5.2.2.
Display of SOS History
SOS History (Number of LED blinking) indication.
From left side; Last SOS, before Last, three occurrence before, 2nd occurrence after shipment, 1st occurrence after shipment.
This indication will be cleared by [Self-check indication and forced to factory shipment setting].
5.2.3.
POWER ON TIME/COUNT
To display TIME/COUNT menu, highlight position, then press MUTE for 3sec. 
Time : Cumulative power on time, indicated hour : minute by decimal
Count : Number of On times by decimal
Note : This indication will not be cleared by either of the self-checks or any other command. 
5.2.4.
Exit
1. Disconnect the AC cord from wall outlet or switch off the power with the [POWER] button on the main unit.