TH-42PHW5UZ - Panasonic Plasma Service Manual (repair manual). Page 16

Read Panasonic TH-42PHW5UZ Service Manual online

10 Alignment
10.1. Pedestal setting
 ** Adjust at the dark room.
1 Component
Picture:
PANEL W/B
 (525i, 525p, 625i,
Normal
R cut off  1) Set R,G and B cut off to " 
80
 ".
  720i or 1080i)
White balance:
G cut off
Cool
B cut off
Gray Scale
Aspect:
Chroma Control:
Pattern
16:9
Gun off  2) Set Gun off to "
5
". (Only green pixels can emit.)
RGB Sub Adjust:
G Sub Bright  3) Adjust G Sub bright to start some of green pixels emission
     at black 2% area and no emission at black 0% area.
Chroma Control:
Gun off  4) Set Gun off to "
3
". (Only blue pixels can emit.)
RGB Sub Adjust:
Black 2 %
B Sub Bright  5) Adjust B Sub bright to start some of blue pixels emission
 Black 0 %
     at black 2% area and no emission at black 0% area.
Chroma Control:
Gun off  6) Set Gun off to "
6
". (Only red pixels can emit.)
RGB Sub Adjust:
R Sub Bright  7) Adjust R Sub bright to start some of red pixels emission
     at black 2% area and no emission at black 0% area.
2 RGB(PC)
Picture:
 1) Change input  to RGB signal.
Gray Scale
Normal PANEL W/B
Pattern
White balance:
R,G,B cut off  2) Repeat procedure 1) to 7) of Component input signal.
Cool
PANEL W/B
Aspect:
R,G,B Drive
16:9
Black 2 %
 Black 0 %
INPUT
Alignment menu
Procedure
Equipment
Setting
16
TH-42PHW5UZ
Page of 49
Display