TH-42PHW5UZ - Panasonic Plasma Service Manual (repair manual)

th-42phw5uz service manual
Model
TH-42PHW5UZ
Pages
49
Size
3 MB
Type
PDF
Document
Service Manual
Brand
Device
Plasma / GPH5D
File
th-42phw5uz.pdf
Date

Read Panasonic TH-42PHW5UZ Service Manual online

Power Source:
AC120V 50/60Hz
Power Consumption: 375 W
2.4W (stand-by condition)
0.9W (Power off condition)
Plasma Display panel: Drive method AC type
50-inch, 16:9 aspect ratio
Contrast Ratio
3000:1
Screen size:
920 mm (W)×518 mm (H)
1,056 mm (diagonal)
No. of pixels
786,432 (1,024 (W)×768 (H))
[3,072×768 dots]
Operating condition:
Temperature
34 °F - 104 °F (0 °C - 40 °C)
Humidity
20 % - 80 %
Horizontal scanning frequency 15.6 - 110kHz
Vertical scanning frequency 48 - 120Hz
Connection terminals:
AV
Video in
1.0 Vp-p (75-ohm)
S-VIDEO IN
(MINI DIN 4PIN)
Y: 1 Vp-p (75-ohm), C: 0.286 Vp-p
(75-ohm)
TH-42PHW5UZ
GPH5D Chassis
AUDIO IN
(RCA PIN JACK × 2)
0.5 Vrms (high impedance)
COMPONENT/RGB
Y/G
1.0 Vp-p/composite (75-ohm)
0.7 Vp-p/non-composite (75-ohm)
P
B
/B
0.7 Vp-p (75-ohm)
P
R
/R
0.7 Vp-p (75-ohm)
HD
1.0 - 5.0 Vp-p (high impedance)
VD
1.0 - 5.0 Vp-p (high impedance)
AUDIO IN
(RCA PIN JACK×2)
0.5 Vrms (high impedance)
PC
(HIGH-DENSITY
D-SUB15PIN)
R,G,B/0.7 Vp-p (75-ohm)
HD, VD/1.0 - 5.0 Vp-p (high
impedance)
AUDIO IN (M3 JACK)
0.5Vrms (high impedance)
SERIAL
EXTERNAL CONTROL
TERMINAL (D-SUB9PIN)
RS-232C COMPATIBLE
SPEAKERS (External
speakers)
6
9
16W [8W+8W] (10% THD)
Dimensions (W×H×D): 40.2” (1,020 mm)×24” (610mm)×3.5” (89
mm)
Weight (Mass)
approx. 66.1 Ibs (29.5 kg) (main unit only)
approx. 75.4 Ibs (33.7kg) (with speakers)
Wide Plasma Display
Specifications
ORDER NO. ITD0207018C0
B02
1 Applicable signals
3
2 Safety Precautions
4
2.1. General Guidelines
4
3 Prevention of Electro Static Discharge (ESD) to
Electrostatically Sensitive (ES) Devices
5
4 About lead free solder (PbF)
6
5 PCB Structure sheet of GPH5D chassis
7
6 Service Hint
8
7 Location of Lead Wiring
9
8 Adjustment Procedure
10
8.1. +B Set-up
10
8.2. Driver Set-up
10
8.3. Initialization Pulse Adjust
11
8.4. P.C.B. (Printed Circuit Board) exchange
12
8.5. Adjustment Volume Location
12
8.6. Test Point Location
12
9 Service mode
13
9.1. CAT (computer Aided Test) mode
13
9.2. IIC mode structure (following items value is sample data.)
15
10 Alignment
16
10.1. Pedestal setting
16
10.2. NTSC panel white balance
17
10.3. PAL/SECAM panel white balance
18
10.4. PC/RGB panel white balance
20
10.5. HD/ 525i /525p panel white balance
22
10.6. 625i panel balance
24
10.7. Sub brightness setting
25
11 Troubleshooting guide
27
11.1. Self Check
27
11.2. No Power
28
11.3. No Picture
29
11.4. Local screen failure
29
12 Option Setting
30
13 Block Diagrams
33
13.1. Main Block Diagram
33
13.2. Power Block Diagram
34
13.3. HX-Board Block Diagram
35
13.4. HZ-Board Block Diagram
36
13.5. D1-Board Block Diagram
37
13.6. D2-Board Block Diagram
38
13.7. C1, C2, C3, and C4-Board Block Diagram
39
13.8. SC-Board Block Diagram
40
13.9. SU-Board Block Diagram
41
13.10. SD-Board Block Diagram
42
13.11. SS-Board Block Diagram
43
13.12. Z-Board Block Diagram
44
14 Parts Location
45
14.1. Parts Location1
45
14.2. Parts Location2
46
14.3. Parts Location3
47
15 Mechanical Replacement Parts List
48
CONTENTS
Page
Page
2
TH-42PHW5UZ
1 Applicable signals
3
TH-42PHW5UZ
2.1.1.
Leakage Current Cold Check
1. Unplug the AC cord and connect a jumper between the two
prongs on the plug.
2. Measure the resistance value, with an ohmmeter, between
the jumpered AC plug and each exposed metallic cabinet
part on the equipment such as screwheads, connectors,
control shafts, etc. When the exposed metallic part has a
return path to the chassis, the reading should be between
1M
9
and 5.2M
9
.
When the exposed metal does not have a return path to
the chassis, the reading must be
.
Figure 1
2.1.2.
Leakage Current Hot Check (See
Figure 1.)
1. Plug the AC cord directly into the AC outlet. Do not use an
isolation transformer for this check.
2. Connect a 1.5k
9
, 10 watts resistor, in parallel with a 0.15µF
capacitors, between each exposed metallic part on the set
and a good earth ground such as a water pipe, as shown in
Figure 1.
3. Use an AC voltmeter, with 1000 ohms/volt or more
sensitivity, to measure the potential across the resistor.
4. Check each exposed metallic part, and measure the
voltage at each point.
5. Reverse the AC plug in the AC outlet and repeat each of the
above measurements.
6. The potential at any point should not exceed 0.75 volts
RMS. A leakage current tester (Simpson Model 229 or
equivalent) may be used to make the hot checks, leakage
current
must
not
exceed
1/2
milliamp.
In
case
a
measurement is outside of the limits specified, there is a
possibility of a shock hazard, and the equipment should be
repaired and rechecked before it is returned to the
customer.
2 Safety Precautions
2.1.
General Guidelines
1. When servicing, observe the original lead dress. If a short circuit is found, replace all parts which have been overheated or
damaged by the short circuit.
2. After servicing, see to it that all the protective devices such as insulation barriers, insulation papers shields are properly
installed.
3. After servicing, make the following leakage current checks to prevent the customer from being exposed to shock hazards.
4
TH-42PHW5UZ
Page of 49
Display

Download Panasonic TH-42PHW5UZ Service Manual (Repair Manual)

Here you can read online and download Panasonic TH-42PHW5UZ Service Manual in PDF. TH-42PHW5UZ service manual will guide through the process and help you recover, restore, fix, disassemble and repair Panasonic TH-42PHW5UZ Plasma. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.