KX-VC500CX/KX-VCA001X
3.3.
Boundary Microphone (KX-VCA001)
Dimensions
Diameter 120 mm x 25 mm (4.7 in x 0.9 in)
Power Input
Supplied from main unit via proprietary cable
Weight
Approx. 280 g (approx. 0.6 lb)
Operating Temperature
°C - 40 °C (32 °F - 104 °F)
Operating Humidity
10 % - 90 % (non-condensing)
Standard Pickup Range
Radius approx. 2 m (approx. 6.5 ft), 360
°
Maximum Pickup Range
Radius approx. 3 m (approx. 9.8 ft), 360
°
Sound Pickup Method
Stereo / Monaural (either output can be set through system settings)
Microphone Unit
Unidirectional ECM microphone parts x 4
Maximum Number of Connected Microphones
4
Bandwidth
150 Hz-10 kHz
Maximum Input Sound Pressure
110 dBspl
Sampling Frequency
48 kHz
Delay Time
1 ms or less
Number of Terminals for Microphone Connection
2
Length of Included Cable
Approx. 8.5 m (approx. 28 ft)
MIC Mute Button
Push Switch
LEDs
Red: The microphone is muted.
Green: The microphone is transmitting.
Orange: The microphone is starting up (flashes for approx. 1 second).
Off: The microphone is not transmitting.
Page of 28