KX-TDE600UC - Panasonic PBX Service Manual (repair manual). Page 6

Read Panasonic KX-TDE600UC Service Manual online

6
KX-TDE600UC
3 Specifications
3.1.
General Description
*1 If tolerance may be exceeded, an Uninterruptible Power Supply (UPS) is recommended.
3.2.
Characteristics
Control Bus
Original bus (16 bit, 8 MHz,10 megabytes per second)
Communication Bus
H.100 bus conformity (1024 time slot)
Switching
Distributed Switching
Power Input
PSU-M
100 V AC to 130 V AC; 2.5 A/200 V AC to 240 V AC; 1.4 A; 50 Hz/60 Hz
PSU-L
100 V AC to 130 V AC; 5.1 A/200 V AC to 240 V AC; 2.55 A; 50 Hz/60 Hz
Maximum Power Failure Tolerance*1
300 ms
Power Consumption (per shelf)
With PSU-M
190 W; 2.5 A (at 120 V AC; 60 Hz)
With PSU-L
410 W; 5.1 A (at 120 V AC; 60 Hz)
Memory Backup Duration
 7 years
Dialling  
CO Line
Dial Pulse (DP) 10 pps, 20 pps
Tone (DTMF) Dialling
Extension 
Dial Pulse (DP) 10 pps, 20 pps
Tone (DTMF) Dialling
Mode Conversion 
DP-DTMF, DTMF-DP
Ring Frequency 
20 Hz/25 Hz (selectable)
Central Office Loop Limit 
1600 
Ω maximum
Operating Environment
Temperature
 0 
°C to 40 °C (32 °F to 104 °F)
Humidity
10%to 90% (non condensing)
Conference Call CO Line (per shelf)
From 10 x 3-party conference call to 3 x 8-party conference call
Music on Hold (MOH)
2 ports (Level Control: -11 dB to +11 dB in 1 dB steps)
MOH1: External Music Source port
MOH2: Selectable Internal/External Music Source port
Paging
Internal
Level Control: -15 dB to +6 dB in 3 dB steps
External
2 ports (Volume Control: -15 dB to +15 dB in 1 dB steps)
Serial Interface Port
RS-232C 
1 (max 115.2 kbps)
RJ45 Port
MNT Port 
1 (for PC connection)
LAN Port
1 (for LAN connection)
Extension Connection Cable
SLT 
1 pair wire (T, R)
DPT 
1-pair wire (D1, D2) or
2-pair wire (T, R, D1, D2)
APT 
2-pair wire (T, R, D1, D2)
PT-interface CS 
1-pair wire (D1, D2)
PT-interface CS (High-density)
4-pair wire (D1, D2)
DSS Consoles and Add-on Key Module
1-pair wire (D1, D2)
Dimension
430 mm (W) x 415 mm (H) x 270 mm (D)
(17-1/5 in  x 16-3/5 in  x 10-4/5 in)
Weight (when fully mounted)
Under 16 kg (35.2 lb.)
Terminal Equipment Loop Limit
• PT: KX-DT300/KX-T7600 series DPT: 90 
Ω; all other DPTs/APTs:40 Ω
• SLT: 600 
Ω including set
• Doorphone: 20 
• CS: 130 
Ω; PT-interface CS: 65Ω
Minimum Leakage Resistance
15000 
Ω maximum
Maximum Number of Extension
Instruments per Line
1 for PT or SLT
2 by Parallel or eXtra Device Port connection of an APT/DPT and an SLT
3 by Digital eXtra Device Port connection of 2 DPTs and an SLT
Ring Voltage
75 Vrms at 20 Hz/25 Hz depending on the Ringing Load
Central Office Loop Limit
1600 
Ω maximum
Hookswitch Flash Timing Range
24 ms to 2032 ms
Door Opener Current Limit
24 V DC/30 V AC, 1 A maximum
External Relay Current Limit
24 V DC/30 V AC, 1 A maximum
External Sensor Current Limit
Power to the external sensor is provided from the EIO4 card and must be grounded through
the EIO4 card. For the connection diagram, refer to EIO4 Card (KX-TDA0164). The PBX
detects input from the sensor when the signal is under 100
Ω.
Paging Terminal Impedance
600 
MOH (Music on Hold) Terminal Impedance
10000 
Page of 127