KX-TDA6110XJ, KX-TDA6110X - Panasonic PBX Service Manual (repair manual). Page 7

Read Panasonic KX-TDA6110XJ / KX-TDA6110X Service Manual online

5.1. INSTALLING/REMOVING THE OPTIONAL SERVICE CARDS
Slot Condition
Card Type
Slot Type
Free 1-10
EMPR
BUS-S
EMPR Card
No
Yes
No
BUS-M Card
No
No
Yes
Trunk Cards
Yes
No
No
Extension Cards
Yes
No
No
OPB3 Card
Yes
No
No
CTI-LINK Card
Yes
No
No
EECHO Card
Yes
No
No
Caution:
To protect the back board from static electricity, do not touch parts on the back board in the main unit and on the optional
service cards.To discharge static, touch ground or wear an earthing strap.
BUS-M connector between shelves
Mount 3 same connectors for the connection to expansion shelves on the basic shelf.
The connector map for inter-shelf connections is described in the table below.
A 20Pair twisted pair cable with 20 pin connectors is assumed as a cable for connection.
Table 0-1 Connector map for connections between shelf #1
A/B
Pin No
Signal Name
Pin No
Signal Name
I/O
Note
A
1
S1_CCLINK_P
2
S1_CCLINK_N
I/O
CircLink Bus
3
S1HWU0_N
4
S1HWU0_P
I
Inter-shelf Hiway(up)#0
5
S1HWU1_P
6
S1HWU1_N
I
Inter-shelf Hiway(up)#1
7
S1HWU2_N
8
S1HWU2_P
I
Inter-shelf Hiway(up)#2
9
S1_NETREF_P
10
S1_NETREF_N
I
Network Reference Signal
11
S1_SHW_nFH_N
12
S1_SHW_nFH_P
O
Inter-shelf Frame header Signal
13
S1_SHW_CLK_P
14
S1_SHW_CLK_N
O
Inter-shelf Hiway Clock(8.192MHz)
15
S1_nRESET_N
16
S1_nRESET_P
O
Expansion shelf Reset Signal
17
S1_RINGSYNC_P
18
S1_RINGSYNC_N
O
Ringer Sync Signal
19
S1HWD0_N
20
S1HWD0_P
O
Inter-shelf Hiway(down)#0
B
1
GND
2
GND
-
Digital Ground
3
S1_CPU_STATUS1_N
4
S1_CPU_STATUS1_P
I
BUS-S Status #1
5
S1_CPU_STATUS0_P
6
S1_CPU_STATUS0_N
I
BUS-S Status #0
7
S1_nLOS0_P
8
S1_nLOS0_N
I
Loss of Sync Signal
9
NSLF_PRS0/(Pull-up)
10
NSLF_PRS0/(GND)
I
Expansion shelf connect Status
11
ESLFID0[0]/GND
12
ESLFID0[1]/GND
O
Extension Shelf ID
13
NC
14
NC
Reserved pin
15
S1_HWD2_P
16
S1_HWD2_N
O
Inter-shelf Hiway(down)#2
17
S1_HWD1_N
18
S1_HWD1_P
O
Inter-shelf Hiway(down)#1
19
GND
20
GND
Digital Ground
Table 0-2 Connector map for connections between shelf #2
A/B
Pin No
Signal Name
Pin No
Signal Name
I/O
Note
A
1
S2_CCLNK_P
2
S2_CCLNK_N
I/O
Circ-Link Bus
3
S2HWU0_N
4
S2HWU0_P
I
Inter-shelf Hiway(up)#0
5
S2HWU1_P
6
S2HWU1_N
I
Inter-shelf Hiway(up)#1
7
S2HWU2_N
8
S2HWU2_P
I
Inter-shelf Hiway(up)#2
9
S2_NETREF_P
10
S2_NETREF_N
I
Network Reference Signal
11
S2_SHW_nFH_N
12
S2_SHW_nFH_P
O
Inter-shelf Frame header Signal
13
S2_SHW_CLK_P
14
S2_SHW_CLK_N
O
Inter-shelf Hiway Clock(8.192MHz)
15
S2_nRESET_N
16
S2_nRESET_P
O
Expansion shelf Reset Signal
17
S2_RINGSYNC_P
18
S2_RINGSYNC_N
O
Ringer Sync Signal
19
S2HWD0_N
20
S2HWD0_P
O
Inter-shelf Hiway(down)#0
B
1
GND
2
GND
Digital Ground
3
S2_CPU_STATUS1_N
4
S2_CPU_STATUS1_P
I
BUS-S Status #1
5
S2_CPU_STATUS0_P
6
S2_CPU_STATUS0_N
I
BUS-S Status #0
7
S2_nLOS0_P
8
S2_nLOS0_N
I
Loss of Sync Signal
9
NSLF_PRS0/(Pull-up)
10
NSLF_PRS0/(GND)
I
Expansion shelf connect Status
11
ESLFID0[0]/(Pull-up)
12
ESLFID0[1]/GND
O
Extension Shelf ID
13
NC
14
NC
15
S2_HWD2_P
16
S2_HWD2_N
O
Inter-shelf Hiway(down)#2
17
S2_HWD1_N
18
S2_HWD1_P
O
Inter-shelf Hiway(down)#1
19
GND
20
GND
Digital Ground
7
KX-TDA6110XJ / KX-TDA6110X
Page of 60
Display