Read Sharp R-22AMM (serv.man3) Service Manual online
R22AMM
3 – 1
R22AMM
Service Manual
CHAPTER 3.
PRODUCT SPECIFICATIONS
[1] SPECIFICATION
[2] APPEARANCE VIEW
1. OVEN
1. Control panel
2. Hole for safety door latches
3. Ceramic floor
4. Splash cover
5. Oven light
6. Air intake filter
7. Air intake openings
8. Oven cavity
9. Door seals and sealing surfaces
10. Door hinges
11. Oven door with see-through window 12. Door safety latches 13. Door handle. 14. Outer cabinet
15. Removable cover over oven light bulb 16. Air vent openings 17. Power supply cord 18 Mounting plate 19 Screw for mounting plate
2. AUTO TOUCH CONTROL PANEL
ITEM
DESCRIPTION
Power Requirements
230 - 240 Volts / 50 Hertz / Single phase, 3 wire earthed
Power Consumption
2.4 kW Approx. 11A
Power Output
1500 W nominal of RF microwave energy (measured by method of IEC 60705)
Operating frequency 2450 MHz
Operating frequency 2450 MHz
Outer Case Dimensions
Width 510 mm
Height 335 mm
Depth 470 mm
Height 335 mm
Depth 470 mm
Cooking Cavity Dimensions
Width 330 mm
Height 180 mm
Depth 330 mm
Height 180 mm
Depth 330 mm
Control Complement
Electronic Timer (0 - 30 minutes)
Microwave Power level
100% 50% 20% 10%
MICROWAVE POWER LEVEL buttons
START button
Microwave Power level
100% 50% 20% 10%
MICROWAVE POWER LEVEL buttons
START button
Net Weight
Approx. 3.3 kg
4
1
5
2
10
3
6
7
9
8
11
12
13
17
16
14
15
19
18
START
HIGH
MEDIUM
MED LOW
DEFROST
TIME
CONTROL
CONTROL
4
5
6
7
8
9
POWER
%
ON
2
1
1
3
DISPLAY AND INDICATORS
Check indicators after the oven starts to confirm the oven
is operating as desired.
1. Cook indicator
is operating as desired.
1. Cook indicator
This indicator shows cooking in progress.
2. Time display
3. Microwave power level display
3. Microwave power level display
OPERATING KEYS
4. HIGH 100%
5. MEDIUM 50%
6. MED LOW 20%
7. DEFROST 10%
8. TIME CONTROL
5. MEDIUM 50%
6. MED LOW 20%
7. DEFROST 10%
8. TIME CONTROL
Rotate the control to enter cooking time.
9. START button
MICROWAVE POWER
LEVEL buttons
LEVEL buttons
R22AMM
3 – 2
[3] INSTALLATION INFORMATION
When this commercial microwave oven is installed near other commercial electrical appliances, connect a lead wire to each equivalent potential ter-
minal with equipotential marking between them (insert a lead wire between a washer and an earth angle, and screw them), as shown in Fig. A-1, to
make sure that they are at equivalent potential. If any lead wire is not connected between them, when person touch them he/she will get a electric
shock.
minal with equipotential marking between them (insert a lead wire between a washer and an earth angle, and screw them), as shown in Fig. A-1, to
make sure that they are at equivalent potential. If any lead wire is not connected between them, when person touch them he/she will get a electric
shock.
Figure A-1
C OMME R C IAL MIC R OW AV E OV E N
OT HE R C OMME R C IAL
E LE C T R IC AL AP P LIANC E
E LE C T R IC AL AP P LIANC E
Lead wire
E quipotential marking
E arth angle
(E quivalent potential terminal)
(E quivalent potential terminal)
E quivalent
potential terminal
potential terminal
S crew
W as her
Lead wire
Display