4 SPECIFICATIONS
4.1. GENERAL DESCRIPTION
Switching
Non Blocking
AC Adapter
AC Input
100 V AC to 240 V AC, 1.5 A, 50 Hz/60 Hz
DC Output
40 V, 1.38 A, (55.2W)
DC Input
    
·
    
DC IN 1:40 V, 1.38 A (55.2 W)
    
·
    
DC IN 2:40 V, 1.38 A (55.2 W)
Maximum Power Failure
Tolerance
300 ms
Memory Backup Duration
7 years
Dialing
Trunk
Dial Pulse (DP) 10 pps, 20 pps
Tone (DTMF) Dialing
Extension
Dial Pulse (DP) 10 pps, 20 pps
Tone (DTMF) Dialing
Connectors
Trunk
RJ11 (2 wire) x each Trunk ports
Extension
RJ11 (4 wire) x each extension ports
Paging Output
1 conductor jack
External MOH
(Music on Hold)
Output
1 conductor jack
Mode Conversion
DP-DTMF, DTMF-DP
Ring Frequency
20 Hz/25 Hz (selectable)
Trunk Loop Limit
1600
maximum
Operating
Environment
Temperature
0 °C to 40 °C
Humidity
10% to 90% (non condensing)
Conference Call Trunk
From 10 x 3-party conference call to 4 x 8-party conference call
Music on Hold
1 port (Level Control: -11 dB to +11 dB in 1 dB steps)
Selectable Tone/External Music Source port
Paging
Internal
Level Control: -15 dB to +6 dB in 3 dB steps
External
1 port (Volume Control: -15 dB to +15 dB in 1 dB steps)
Serial Interface Port
RS-232C
1 (max 115.2 kbps)
USB
1
Extension Connection Cable
SLT
1 pair wire (T, R)
DPT
1-pair wire (D1, D2) or 2-pair wire (T, R, D1, D2)
APT
2-pair wire (T, R, D1, D2)
DSS Console and Add-on Key Module
1-pair wire (D1, D2)
Dimension
275 mm (W) x 376 mm (H) x 117 mm (D)
(10 4/5 in x 14 4/5 in x 4 3/5 in)
Weight (when fully mounted)
Under 3.5 kg (7.72 lb)
4.2. CHARACTERISTICS
Terminal Equipment Loop Limit
    
·
    
PT: KX-T7600 series: 90
; all other DPTs/APTs: 40
    
·
    
SLT: 600
including set
    
·
    
Doorphone: 20
    
·
    
CS: 65
Minimum Leakage Resistance
15000
maximum
Maximum Number of Extension
Instruments per Line
1 for PT or SLT
2 by Parallel or eXtra Device Port connection of a PT and an SLT
3 by Digital eXtra Device Port connection of two DPTs and an SLT
Ring Voltage
75 Vrms at 20 Hz/25 Hz depending on the Ringing Load
Trunk Loop Limit
1600
maximum
Hookswitch Flash/Recall Timing Range
24 ms to 2032 ms
BRI Cards Internal ISDN Mode
Supply Voltage: 40 V
Power Supply: 4.5 W per 1 line, 5 W per 2 lines
Power Supply Method: Phantom Power Supply
Door Opener Current Limit
24 V DC/30 V AC, 1 A maximum
Paging Terminal Impedance
600
MOH Terminal Impedance
10000