4.3.3. Power Supply Unit Selection
Main unit (Hybrid IP-PBX) needs an optional power supply unit (PSU) suitable for its configuration. Calculate the amount of
"load figures" from the type and number of equipment to be connected, and determine the type of PSU that will be required.
Load Figure Calculation
Equipment Type
Load Figure
PT
KX-T7600 series DPT/DSS console
1
KX-T7560/KX-T7565 DPT
1
Other DPT/DSS console
4
APT
4
IP-PT
0
Extension Card *1
DHLC8
8
SLC8
8
SLC16
16
MSLC16
16
CS (1 unit)
4
PT-interface CS (1 unit)
4
ISDN Extension
2
VPS (1 port)
1
*1 Only the extension cards that can support SLTs count for the load figures.
PSU Capability
Each PSU supports a different amount of load figures.
PSU Type
Maximum Load Figures
PSU-M *2
128
PSU-L
512
*2 Available for the KX-TDA100 and KX-TDA200.